Texas Instruments Development Kit for TM4C129x,Tiva™ ARM® Cortex™ -M4 Microcontroller DK-TM4C129X DK-TM4C129X 데이터 시트

제품 코드
DK-TM4C129X
다운로드
페이지 2182
Description
Reset
Type
Name
Bit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0
RO
reserved
31:8
General-Purpose Timer 7 Power Control
The
Pn
bit encodings are not applicable if the corresponding bit in the
RCGCTIMERSCGCTIMER or DCGCTIMER register is clear.
Description
Value
Timer 7 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 7 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1
RW
P7
7
General-Purpose Timer 6 Power Control
The
Pn
bit encodings are not applicable if the corresponding bit in the
RCGCTIMERSCGCTIMER or DCGCTIMER register is clear.
Description
Value
Timer 6 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 6 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1
RW
P6
6
General-Purpose Timer 5 Power Control
The
Pn
bit encodings are not applicable if the corresponding bit in the
RCGCTIMERSCGCTIMER or DCGCTIMER register is clear.
Description
Value
Timer 5 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 5 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1
RW
P5
5
General-Purpose Timer 4 Power Control
The
Pn
bit encodings are not applicable if the corresponding bit in the
RCGCTIMERSCGCTIMER or DCGCTIMER register is clear.
Description
Value
Timer 4 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 4 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1
RW
P4
4
December 13, 2013
476
Texas Instruments-Advance Information
System Control