Texas Instruments TPA2016D2 Evaluation Module (EVM) TPA2016D2EVM TPA2016D2EVM 데이터 시트

제품 코드
TPA2016D2EVM
다운로드
페이지 13
www.ti.com
Operation
2. The TPA2016D2 software interface is as shown in
Figure 4. Software Interface
Note:
The TPA2016D2 powers up with the amplifier in software shutdown. To hear an output,
uncheck shutdown.
3. Uncheck and check Left Enable or Right Enable to place the corresponding channels in and out of
SHUTDOWN.
4. Click Shutdown to place the TPA2016D2 in and out of SOFTWARE SHUTDOWN.
5. Adjust the Attack Time, Release Time and Hold Time by sliding the bar or clicking the tap in the GUI.
You can also type a value in the box; in that case, the value will be rounded to the closest available
setting.
6. Adjust the Fixed Gain, Minimum Gain and Limiter Level by dragging the bar or clicking the tap in the
GUI. You can also type a value in the box; in that case, the value will be rounded to the closest
available setting.
7. Adjust Compression Ratio and Noise Gate Threshold by clicking the value.
8. The Limiter Power Level can be calculated by selecting the Load Resistance.
9. I2C Status box reports the status of I
2
C communications. An error or failure has occurred if it shows
I2C failure.
10. To read the I
2
C status, click Refresh.
11. Thermal box reports the status of thermal failure. A thermal fault has occurred if it turns red.
SLOU201 – June 2008
TPA2016D2EVM
5