Texas Instruments TPA2016D2 Evaluation Module (EVM) TPA2016D2EVM TPA2016D2EVM 데이터 시트

제품 코드
TPA2016D2EVM
다운로드
페이지 13
2.1.4
Shutdown Control
2.2
Quick Start List When Connected to Existing Circuits With I
2
C Controls
2.2.1
Evaluation Module Preparations
Operation
www.ti.com
12. The GUI has a built-in I
2
C programming interface. Follow the steps below to use the I
2
C programming
function.
At the top left corner of the GUI, click File to access the I
2
C programming interface.
Save Script can record the current register values. Select Save Script >> Click the folder icon to
browse to the place where you want to save the script >> name the file in text format, then select
OK to save.
Load Script can load the previously saved script to program the entire register file. Select Load
Script >> Click the folder icon to browse to the place where the script is located >> Select the file
then click OK >> Click Load.
I2C interface can program individual register value of TPA2016D2. Select I
2
C Interface >> I
2
C
address is xB0, which is the address of TPA2016D2. Device address is from 1 to 7, which is the
register address of TPA2016D2.
The TPA2016D2 EVM provides independent hardware shutdown controls for the Class-D power amplifier
and the USB controller.
1. Press and hold push button SDN to shutdown TPA2016D2. Release SDN to activate TPA2016D2.
2. Press and hold push button RST to shutdown the USB controller. Release RST to activate the USB
controller.
The TPA2016D2EVM can be easily connected to existing circuits with I
2
C controls. Connections to the
EVM module can be made using banana plugs for the power supply. The inputs accept standard RCA
plugs and the outputs accept banana connectors.
1. Ensure that all external power sources are set to OFF.
2. Install shunts in jumpers JP4.
3. Remove shunts between JP2 and JP3 and connect I
2
C controls to JP3 as shown in
Figure 5. Connect I
2
C Controls to JP3
4. Install shunts in jumpers JP5 and JP6 when single-ended audio inputs are used; this ties INL– and
INR– to ground.
5. Remove JP1.
6. Connect an external regulated power supply adjusted for 2.5 V–5.5 V to the module VDD (J8) and
GND (J7) banana jacks, taking care to observe marked polarity.
7. Connect audio source to J4 and J3.
6
TPA2016D2EVM
SLOU201 – June 2008