Texas Instruments CC2650DK 사용자 설명서
Idle
Idle
Mater operates in master
receive mode.
Stop condition is not
generated.
Write slave address
to I2C_MSA
Write 0-011 to
I2C_MCTRL
Master operates in master
transmit mode.
Repeated Start condition is
generated with changing data
direction.
Functional Description
Figure 21-12. Master TRANSMIT With Repeated Start After RECEIVE With Repeated Start Condition
1389
SWCU117A – February 2015 – Revised March 2015
Inter-Integrated Circuit (I
2
C) Interface
Copyright © 2015, Texas Instruments Incorporated