Texas Instruments INA230 Evaluation Module INA230EVM INA230EVM 데이터 시트

제품 코드
INA230EVM
다운로드
페이지 31
INA230EVM Software Overview
In addition to the INA230EVM software alert configuration, the Alert Configuration box includes the
Conversion Ready button that allows for a special functionality on the Alert pin. When the INA230
completes the conversions for its current operation, it triggers the Alert pin and notifies the user that
another conversion can be performed. In most cases, the INA230 conversion ready flag is not visible
because of the speed of the INA230 conversion process.
5.3
Using the INA230EVM Software
After configuring the INA230EVM software, the rest of the tabs can be evaluated. This section describes
the basic operation of the device, and offers guidelines for interpreting the graphic user interface (GUI).
5.3.1
INA230 Bus Voltage, Shunt Voltage, Current, and Power Reading Bar
The bottom bar of the INA230 software, as shown in
allows the user to constantly check the
status of the INA230 unit itself. These values are updated each time the Read All Reg button is pressed
at the top of the software. In addition to the register values stored in the part, the software also includes
flags for when the part is ready to trigger another conversion and when the Alert pin is triggered.
Figure 22. INA230 Results Bar
5.3.2
Calculation and Theory of Operation
The Calculation tab, as shown in
allows the user to follow the software flow with basic
calculations performed from within the device. It is important to note that the calculations are performed
with the decimal values of the corresponding registers.
Figure 23. Theory of Operation Flowchart on the Calculation Tab
20
INA230EVM Evaluation Board and Software Tutorial
SBOU124 – March 2012
Copyright © 2012, Texas Instruments Incorporated