Texas Instruments IC MCU 16B MSP430F167IPM LQFP-64 TID MSP430F167IPM 데이터 시트

제품 코드
MSP430F167IPM
다운로드
페이지 77
MSP430F15x, MSP430F16x, MSP430F161x
MIXED SIGNAL MICROCONTROLLER
SLAS368G − OCTOBER 2002 − REVISED MARCH 2011
26
POST OFFICE BOX 655303 
 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted)
MSP430F15x/16x supply current into AV
CC
 + DV
CC
 excluding external current (AV
CC
 = DV
CC
 = V
CC
)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
Active mode, (see Note 1)
f
(MCLK)
 = f
(SMCLK)
 = 1 MHz,
T
40
°
C to 85
°
C
2.2 V
330
400
A
I
f
(MCLK)
 = f
(SMCLK)
 = 1 MHz,
f
(ACLK)
 = 32,768 Hz
XTS=0,  SELM=(0,1)
T
A
 = −40
°
C to 85
°
C
3 V
500
600
μ
A
I
(AM)
Active mode, (see Note 1)
f
(MCLK)
 = f
(SMCLK)
 = 4,096 Hz,
T
40
°
C to 85
°
C
2.2 V
2.5
7
A
f
(MCLK)
 = f
(SMCLK)
 = 4,096 Hz,
f
(ACLK)
 = 4,096 Hz
XTS=0,  SELM=3
T
A
 = −40
°
C to 85
°
C
3 V
9
20
μ
A
I
Low-power mode, (LPM0)
f
(MCLK)
 = 0 MHz, f
(SMCLK)
 = 1 MHz,
f
32 768 Hz
T
40
°
C to 85
°
C
2.2 V
50
60
A
I
(LPM0)
(
)
(
)
f
(ACLK)
 = 32,768 Hz
XTS=0,  SELM=(0,1)
(see Note 1)
T
A
 = −40
°
C to 85
°
C
3 V
75
90
μ
A
I
Low-power mode, (LPM2),
f
f
0 MHz
T
40
°
C to 85
°
C
2.2 V
11
14
A
I
(LPM2)
f
(MCLK)
 = f
(SMCLK)
 = 0 MHz,
f
(ACLK)
 = 32.768 Hz,  SCG0 = 0
T
A
 = −40
°
C to 85
°
C
3 V
17
22
μ
A
T
A
 = −40
°
C
1.1
1.6
Low-power mode (LPM3)
T
A
 = 25
°
C
2.2 V
1.1
1.6
I
Low-power mode, (LPM3)
f
(MCLK)
 = f
(SMCLK)
 = 0 MHz,
T
A
 = 85
°
C
2.2 V
2.2
3.0
A
I
(LPM3)
f
(MCLK)
 = f
(SMCLK)
 = 0 MHz,
f
(ACLK)
 = 32,768 Hz,  SCG0 = 1
(
N t 2)
T
A
 = −40
°
C
2.2
2.8
μ
A
(ACLK)
(see Note 2)
T
A
 = 25
°
C
3 V
2.0
2.6
T
A
 = 85
°
C
3 V
3.0
4.3
Low-power mode, (LPM4)
T
A
 = −40
°
C
0.1
0.5
I
(LPM4)
Low-power mode, (LPM4)
f
(MCLK)
 = 0 MHz, f
(SMCLK)
 = 0 MHz,
T
A
 = 25
°
C
2.2V / 3 V
0.2
0.5
μ
A
I
(LPM4)
f
(MCLK)
   0 MHz, f
(SMCLK)
   0 MHz,
f
(ACLK)
 = 0 Hz, SCG0 = 1
T
A
 = 85
°
C
2.2V / 3 V
1.3
2.5
μ
A
NOTES:
1. Timer_B is clocked by f
(DCOCLK)
 = 1 MHz. All inputs are tied to 0 V or to V
CC
. Outputs do not source or sink any current.
2. WDT is clocked by f
(ACLK)
 = 32,768 Hz. All inputs are tied to 0 V or to V
CC
. Outputs do not source or sink any current. The current
consumption in LPM2 and LPM3 are measured with ACLK selected.
Current consumption of active mode versus system frequency
I(AM) = I(AM) [1 MHz]
 
×
 f(System) [MHz]
Current consumption of active mode versus supply voltage
I
(AM)
 = I
(AM) [3 V] 
+ 210 
μ
A/V 
×
 (V
CC
 – 3 V)