13
 
 
Timing 
The shortest polling cycle is 1 second, i.e. signals shorter than 1 second will 
generally not be recognized. 
The object instances are not automatically queried if the INSYS GSM 4.2 easy is 
busy with the following actions: 
¾
  Field strength query and login state query, duration approx. 5s, interval 60s, 
may be switched off. 
¾
  SMS input buffer and processing of SMS, duration approx. 5s, interval 60s, may 
be switched off. 
¾
  Established GSM connection (data connection, DTMF connection, security 
callback)  
Sending an SMS (fault message, Alive SMS may be switched off, Power up SMS 
may be switched off, duration approximately 10 seconds.) 
For the values to be monitored applies that all changes must be effective until the 
automatic polling is performed again. This applies to most applications (e.g. fill 
level monitoring or protective motor switch).  
Monitoring with INSYS GSM 4.2 easy is mainly intended for static signals and 
values. 
If the used signal (e.g. pulse) does not comply with these requirements, this signal 
must be directed to an ON or OFF delay or a RS flip-flop in the control program. 
 
Occurrence of several faults/changes 
If several changes occur during a polling interval, the according messages are sent 
in the same order in which they were set during the configuration of the INSYS 
GSM 4.2 easy. The monitored value 1 is therefore queried prior to the monitored 
value 2. If exceeding or changing of values is detected, the system will 
immediately attempt to send the alarm message.  
If another monitored value changes during the alarm processing, this new alarm 
is only detected if the value change lasts until the processing of the previous 
alarm is completed. Now the regular polling will restart.