Ansmann Powerline 5 LCD 5707083 데이터 시트

제품 코드
5707083
다운로드
페이지 42
GB
 
OPERATING INSTRUCTIONS POWERLINE 5 LCD
Please read the operating instructions before use!
USE OF THE CHARGER
Charger with LCD Display and discharge function for 1-4 NiCD/NiMH batteries of the sizes Micro (AAA); Mignon (AA); 
Baby (C); Mono (D) and 1-2 9V block.
ATTENTION
Use only with NiCD/NiMH cells. Non rechargeable batteries or other types could cause an explosion! 
•  Do not attempt to charge Alkaline batteries or other types of primary batteries • Do not dispose of batteries in fire as 
the battery may explode, leak or catch fire
FEATURES
Separate charging processes for each inserted cell; Automatic start of charging at contact with the cell; NiCD as well as 
NIMH cells can be charged at the same time; Microprocessor controlled charging for cylindrical cells; Automatic switch-
over to trickle charging for cylindrical cells; Discharging option for cylindrical cells; Faulty cell detection for cylindrical 
cells
Display for cylindrical cells (1):
LED flashing red
: charging
LED blinking (fast) red: faulty cell
LED flashing yellow: discharging
LED flashing green: ready /trickle charge
Display for 9V block (2):
LED flashing red
: charging
LCD Display for cylindrical cells (3):
Additional information about the charging status and about the capacity level can be seen. (see drawing).
In rotation the charging status (charging or discharging) will be shown. Additionally the capacity of the inserted cells will 
be shown in 25% steps for around 3 seconds. “OK” means end of charge / trickle charge; “BAD” means faulty cell.
Discharge button (4)
Press this button (PRESS) for approx. 3 seconds to start the discharge function for the cylindrical cells.
SAFETY INSTRUCTIONS:
Keep the charger in a dry place (indoor or in-vehicle use only) • In order to avoid the risk of fire and / or electrical 
shock, the charger must be protected against high humidity and water • Ensure that the ventilation slots are kept free,