Technical Data 
3.3 Terminal 
Layout 
The terminals are designed as screw terminals and are located on the top and bottom of 
the cover. 
View of the cover top 
1
2
4
5
6
7
8
9
10
3
INSYS WLAN serial
INSYS WLAN bridge
INSYS MICROELECTRONICS GmbH
Internet: www.insys-tec.de
Sales: insys@insys-tec.de
Support: support@insys-tec.de
GND
50...80 VDC
GND
GND
Reset
GND
Input 1
Input 2
GND
10...60 VDC
 
 
Layout of the terminals on the cover top 
 
Terminal Labeling 
Description 
1 GND 
Ground 
50...80 VDC 
Supply voltage input 50 – 80 V DC (optional) 
10...60 VDC 
Supply voltage input 10 – 60 V DC  
4 GND 
Ground 
5 GND 
Ground 
6 Reset  Reset 
input 
7 GND 
Ground 
Input 1 
Digital input 1 
Input 2 
Digital input 2 
10 GND 
Ground 
 
Attention! 
For series devices, the supply voltage input for the range 50 – 80 V DC at 
terminal 2 is not equipped. If required, devices with this supply voltage 
input may be ordered. 
 
View of the cover bottom 
OUT 1-NC
OUT 1
OUT 2-NC
OUT 2
OUT 2-NO
OUT 1-NO
11
12
14
15
16
13
 
 
 
 