Table 20. DR_STATUS field descriptions (continued)
Field
Description
5
YOW
Y-axis data overwrite
• Asserted whenever a new Y-axis acquisition is completed before the retrieval of the previous data.
When this occurs, the previous data is overwritten.
• Cleared anytime the OUT_Z_MSB (and respectively OUT_Y_MSB, OUT_X_MSB) register is
read.
0: No data overwrite has occurred
1: Y-axis data overwrite occurred before the previous data was read
4
XOW
X-axis data overwrite
• Asserted whenever a new X-axis acquisition is completed before the retrieval of the previous data.
When this occurs, the previous data is overwritten.
• Cleared anytime the OUT_Z_MSB (and respectively OUT_Y_MSB, OUT_X_MSB) register is
read.
0: No data overwrite has occurred
1: X-axis data overwrite occurred before the previous data was read
3
ZYXDR
X-, Y-, and Z-axis data available
• Signals that a new acquisition for any of the channels is available.
• Cleared when the high-bytes of the data of all channels (OUT_X_MSB, OUT_Y_MSB,
OUT_Z_MSB) are read.
0: No new data is ready
1: New data is ready
2
ZDR
Z-axis new data available
• Asserted whenever a new Z-axis data acquisition is completed.
• Cleared anytime the OUT_Z_MSB register is read.
0: No new Z-axis data is ready
1: New Z-axis data is ready
1
YDR
Y-axis new data available
• Asserted whenever a new Y-axis data acquisition is completed.
• Cleared anytime the OUT_Y_MSB register is read.
0: No new Y-axis data is ready
1: New Y-axis data is ready
0
XDR
X-axis new data available
• Asserted whenever a new X-axis data acquisition is completed.
• Cleared anytime the OUT_X_MSB register is read.
0: No new X-axis data is ready
1: New X-axis data is ready