Handling
• Never switch on the amplifier or connect it to a mains socket right after it was taken from a cold to a warm room.
The resulting condensation may destroy the device.
Let the amplifier reach room temperature before plugging it in and switching it on. Wait until the condensation
has evaporated.
• Never pull the mains plug from the mains socket by the cable. Only pull it from the mains socket by the intended
grip areas.
• Unplug the mains plug from the mains socket if you are not using the device for an extended period of time.
• Make sure the amplifier is sufficiently ventilated when in operation. During operation, keep a minimum distance
of 15 cm around the device. The fan openings must not be covered. Always remove both rack covers in operation
if the device is rack-mounted!
• Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety.
• Do not listen to excessively loud music over an extended period of time. This may damage your hearing.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household waste!
Dispose of the product according to the applicable statutory provisions at the end of its service life.
Technical Data
Operating voltage .............................................................. 220 - 240 V/50 - 60 Hz
Fuse .................................................................................... T1.6AL/250 V (5 x 20 mm)
Output performance (RMS / max.) ................................... 2 x 100/160 W (4 Ohm)
Frequency response .......................................................... 10 - 30,000 Hz
Dimensions ........................................................................ 483 x 65 x 185 mm (1.5 HE)
Weight ................................................................................ 4.5 kg