5.7.1 PTZ Channel 
This is the channel that PTZ is connected to. 
5.7.2 PTZ Protocol
From this field, select the PTZ device 
protocol. It must be consistent with the 
protocol of the actual PTZ cameras installed. 
There are two available options: Pelco-D 
and Pelco-P. The changes will take effect 
after clicking “
” to save the changes 
and exiting the menu. 
5.7.3 PTZ Baud Rate 
Select the PTZ device baud rate. It must be consistent with the baud rate of the actual PTZ 
cameras installed. This system supports four options: 1200, 2400, 4800 and 9600. The changes 
will take effect after clicking “
” to save the changes and exiting the menu. 
5.7.4 PTZ Data Bit 
The options for the PTZ Data Bit are “5”, “6”, “7” and “8”. The default setting is “8”. 
5.7.5 PTZ Stop Bit 
The PTZ Stop Bit options are “1” and “2”. The default setting is “1.” 
5.7.6 PTZ Parity 
The PTZ parity options are: “None”, “Odd”, “Even”, “Mark” and “Space”. The default setting 
is “None.” 
5.7.7 PTZ Address 
In this field, select the PTZ device ID. It must be consistent with the ID of the actual PTZ 
cameras installed. Choose any number from 1 to 255, but note that this is not the same as the 
number of the channel to which the PTZ camera is connected in the DVR system. The changes 
will take effect after clicking “
” to save the changes and exiting the menu
Note that the abovementioned channel setting must match the settings of the PTZ camera. 
Note: When making changes to PTZ camera functionality / 
settings, make sure that these changes are being made to actual 
PTZ cameras by selecting the correct number in the previous 
field (Camera Channel).