Cleaning The Electronic Cells
For peak efficiency, the Electronic Cells in
your Air Cleaner should be washed
regularly (between one and six months).
This is necessary to remove the deposits
of dirt particles collected while running.
Experience will be the best indicator of
how often the cells should be washed.
Removing The Electronic Cells And
Pre-filter
CAUTION
!
 To reduce the risk of
electrical shock, disconnect power
to the Air Cleaner before perform-
ing maintenance or service.
1. At the thermostat, place the system
switch to OFF and the fan switch to
AUTO to assure that the air system will
not turn on while cleaning.
2. Push the Electronic Air Cleaner power
switch to the “OFF” position. Unplug
power cord at the wall before removing
the Electronic Cells. If you are not
familiar with this equipment, contact
your installer or dealer.
CAUTION
!
 High voltage is
present within the air cleaner for
operation. Before removing the
power door, wait at least 15 sec-
onds to allow the power pack and
electronic cells to discharge.
3. Turn the latches on the power door 1/4
turn (open position) to unlock and
remove the power door.
4. Remove the Pre-filter.
5. Slide the Electronic Cells out.
Soaking
The dirt on the Electronic Cells can be
removed by soaking in a strong solution of
dishwasher detergent.
1. Use a container large enough to hold
the Electronic Cells, such as a large
plastic dishpan, trash container, or
laundry tub.
2. Use an automatic dishwasher deter-
gent in hot water. All major brands
worked well in tests.
NOTE: Depending on the minerals in the
water in your area, some brands of
dishwasher detergent may form a
precipitate of scum. If a noticeable
scum floats to the surface, try another
brand of detergent.
3. Pour into the container about 3/4 cup
of detergent per cell. A bit more if the
container is much larger than the cell.
Pour in enough very hot water to
cover the cells.
4. After the detergent has completely
dissolved, put the cells in to soak.
5. Soak the cells and pre-filter for 15 to 20
minutes; slosh up and down, or around
several times, and remove.
CAUTION
!
 Be careful not to scald
hands and arms when using very hot
water.
6. Rinse the cells and pre-filter with a fine
lower pressure spray.
7. Soak the cells (only)  in clean hot water
for another 5 to 15 minutes.
8. Remove the cells and let drain for 15 to
20 minutes. If the water draining from
the cells feels slippery, the cells need
more rinsing.
9. Inspect the cells for cleanliness. If any
dirt remains, repeat the washing
procedure until clean.
10. Replace the cells and pre-filter into the
Air Cleaner when dry.
NOTE: If washing must be repeated, this is
an indication that washing should be
performed more frequently.
Replacing The Electronic Cells And
Pre-filter
NOTE: A guide key in the Air Cleaner
cabinet will allow the Electronic Cells to
fit into the cabinet in only one position -
with the arrow pointing in the direction
of airflow.
1. Position cells correctly and slide them
into place.
2. Insert the Pre-filter in the channel
provided for it.
3. Replace the power door. Turn the
latches 1/4 turn to secure the door.
4. Restore all power previously discon-
nected - See Item #2 under Removing
The Electronic Cells And Pre-filter
5. Push the Electronic Air Cleaner switch
to the “ON” position.
Cleaning The Air Flow Switch
During normal maintenance, the air flow
sensor tube may require cleaning to
remove any accumulated dirt and dust.
To clean the tube, gently push a soft pipe
cleaner into the tube above and below the
printed circuit board. Gently blow into the
tube to remove loosened dirt.
Clean above and
below circuit
board in 
air flow
tube.
Cleaning the Ionizing Wires
Ionizing wires may become coated
causing loss of cleaning ability by the
collecting cell and should be cleaned, at
least, annually.
The thin ionizing wires are sharp and
fragile. Use care when wiping the wires
with the pencil eraser to avoid personal
injury or broken wires. If an Ionizing wire
breaks, refer to “Replacing An Ionizing
Wire”.
Using a pencil eraser, wipe each ionizing
wire, exercising care to avoid damage to
them.
Ionizing
Wire
Ionizing
Wire
Pencil
Eraser
Pencil
Eraser
Simple Maintenance Procedures.