Installer Settings
There are a number of 'Installer Settings' that should be set on 
installation.
These can be found under the 'SET UP MENU' on page 15  of 
the user instructions.
The  TPI  Cycles  setting  and  Optimum  Start  settings  should  be 
carefully set on installation as this will affect system performance.
Clock Format
AM/PM or 24 Hour clock display - Default 
setting AM/PM
Daylight saving
On or Off - Default setting ON for UK Market
Standby temperature
Frost protection setting – Default setting 5°C
Upper and Lower 
Default settings 30°C and 5°C
Temperature limits
TPI Cycles
This setting will change according to the 
type of boiler being used - Default setting 6 
For Gas boiler this setting should be 6 
cycles per hour
For Oil boilers this setting should be 3 
cycles per hour
For Electric panel heaters this should be 12 
cycles per hour
Optimum Start
On or Off – Default setting Off