DANGER
Do not use an open flame to ch e ck for gas
l e a k s . Be  sure  there  are  no  sparks  or  open
flames in the area while you ch e ck for leaks.
This  will  result  in  a  fire  or  explosion  which
can cause serious bodily injury or death and
d a m age to pro p e rt y.
Remove control panel burner control knobs,
and front panel
Front edge of the
control panel
Put your fingers under the front edge of the control panel,
lift up, and pull evenly toward you. Figure 22 (a).
The control panel is separate from the front panel. The
control panel needs to be removed before the front panel
can be removed. Figure 21.
Figure 21
Figure 22
(a)
Front Panel
Control Panel
Control
panel
Front
panel
Pull the front panel up and out of the cooking box
assembly. Figure 23.
Figure 23
Front panel
CHECK FOR GAS LEAKS
WARNING: You should check for gas leaks every time
you disconnect and reconnect a gas fitting.
You will need:  a soap and water solution and a rag or
brush to apply it.
Note: Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
Warning: Make sure all burner control knobs are in
the OFF position, including the side burner, if the
barbecue has a side burner.
Turn on gas supply.
WARNING
The  gas  connections  of  your Weber  Gas
Barbecue  have  been  factory  tested. We  do
h ow ever recommend that you leak ch e ck  all
gas  connections  before  operating  yo u r
Weber Gas Barbecue.
To regulator
To regulator