Codepad Indicators 
EN | 12 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
•  Section 3.5 to arm the system in STAY Mode 2.   
•  Section 5.1.5 to use the Installer Code to set zones 
to be automatically isolated in STAY Mode 2. 
•  Section 5.2.6 to use the Master Code to set zones 
to be automatically isolated in STAY Mode 2. 
System Disarmed 
 
This indicator lights with the OFF 
indicator when the system is disarmed. 
MAINS Indicator 
 
The MAINS indicator displays whether 
the systems AC MAINS supply is 
normal or failed. 
When programming in Installer’s Programming 
Mode or using a Master Code function, the MAINS 
indicator lights to indicate a location value from 10 to 
15. The MAINS indicator represents the 10 digit, 
which is added to the value of the lit zone indicator 
(for example, if the value programmed in a location 
is 12, the MAINS and Zone 2 indicators light). 
Table 9: 
MAINS Indicator 
 
Indicator 
Definition 
On 
The AC MAINS power normal. 
Flashing 
The AC MAINS supply failed. 
FAULT indicator 
 
The FAULT indicator lights when the 
system detects a system fault (refer to 
Table 7 on page 11). Refer to Section 3.12 
Fault Analysis Mode
 on page 18 for more 
information on system faults. 
Each time a new system fault is detected (the FAULT 
indicator flashes), the codepad beeps once per min. 
Press [AWAY] to stop the beeping and acknowledge 
the fault. 
Programming Mode 
 
Flashing 
These two indicators flash when you 
enter Installer’s Programming Mode or 
use any Master Code function. 
OFF Indicator/Zone Sealed 
 
The OFF indicator lights when the 
system is disarmed and flashes when a 
zone becomes unsealed when disarmed. 
The indicator stops flashing when all 
zones are sealed. 
ON Indicator/Zone in Alarm 
 
The ON indicator lights when the 
system is armed and flashes when an 
alarm occurs. The indicator is reset after 
a valid User Code is entered. 
Audible Indicators 
The codepad provides a number of audible 
indications. Refer to Table 8 on page 11. 
2.3 
ICP-CP500PW Master Partitioned 
LED Codepad 
Figure 3:  ICP-CP500PW Master Partitioned 
Codepad 
 
This codepad is used only on a partitioned 
ICP-CC488 Control Panel. The Master Partitioned 
LED codepad allows a user to operate both areas 
individually from the same codepad, without the 
need to operate individual areas from separate 
codepads. 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad incorporates a number of indicators: 
eight zone indicators show the condition of each 
zone, eight area indicators show the area status,  and 
four other indicators show general status. These 
indicators are described in the tables throughout this 
section. 
Zone Indicators 
The zone indicators (1 to 8) show the status of each 
zone as defined in Table 3 on page 10. The zones 
belong to the area with the lit Area Display indicator. 
AREA ON/OFF Indicators 
The group of four Area On/Off indicators shows the 
status of each area as defined in Table 10 on page 13.  
If an area is armed in STAY Mode 1, the 
corresponding Area On/Off indicator is lit in 
conjunction with the PARTIAL indicator. If the area 
is armed in AWAY Mode, only the ON/OFF 
indicator is lit.