Bosch Appliances Home Security System ICP-CC488 사용자 설명서

다운로드
페이지 118
ICP-CC488 | Installation Guide | 2.0  
Codepad Indicators 
EN | 13 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
Table 10:  Area On/Off Indicators 
 
Indicator 
Definition 
On 
The area is armed in AWAY 
Mode or STAY Mode 1. 
Off 
The area is disarmed. 
Area Display Indicators 
The group of four Area Display indicators shows the 
area to which the eight zones belong. For example, if 
the Area 1 indicator is lit, the Zones indicators 
correspond to the zones assigned to that area. 
Press [AWAY] to move to the next area display. For 
example, if the Area 1 indicator is lit, pressing 
[AWAY] extinguishes the Area 1 indicator and lights 
the Area 2 indicator. 
Table 11:  Area Display Indicators 
 
Indicator 
Definition 
On 
Information is displayed for the area. 
Off 
Information is not displayed for the area. 
AUX Indicator 
If Options 8 is selected in Location 500 (refer to 
Section 19.3.1 Partitioning Options 1 on page 85), the 
AUX indicator lights when the control panel is using 
the telephone line. The AUX indicator also flashes 
with the PARTIAL indicator when Installer’s 
Programming Mode or Master Code functions are 
used. 
Table 12:  AUX Indicator 
 
Indicator 
Definition 
On 
The control panel is using the 
telephone line. 
Off 
The control panel is not using the 
telephone line. 
Flashing 
Installer’s Programming Mode or a 
Master Code function is active. 
MAINS Indicator 
The MAINS indicator shows the status of the AC 
MAINS supply (refer to Table 6 on page 11).  
When programming in Installer’s Programming 
Mode or using a Master Code function, the MAINS 
indicator lights to indicate a location value from 10 to 
15. The MAINS indicator represents the 10 digit, 
which is added to the value of the lit zone indicator 
(for example, if the value programmed in a location 
is 12, the MAINS and Zone 2 indicators light). 
FAULT indicator 
The FAULT indicator lights when the system detects 
a system fault (refer to Table 7 on page 11). Refer to 
Section 3.12 Fault Analysis Mode on page 18 for more 
information on system faults. 
Each time a new system fault is detected (the FAULT 
indicator flashes), the codepad beeps once per min. 
Press [AWAY] to stop the beeping and to 
acknowledge the fault. 
PARTIAL Indicator 
The PARTIAL indicator lights when the system is 
armed in STAY Mode 1. The PARTIAL indicator 
flashes with the AUX indicator when Installer’s 
Programming Mode or a Master Code function is 
active. Refer to Table 13 on page 13. 
Table 13:  PARTIAL Indicator 
 
Indicator 
Definition 
On 
The system is armed in STAY Mode 1. 
Off 
The system is not armed in STAY Mode 1. 
Flashing 
Installer’s Programming Mode or a Master 
Code function is active. 
Audible Indicators 
The codepad provides a number of audible 
indications. Refer to Table 8 on page 11. 
2.4 
ICP-CP516 Sixteen Zone Codepads 
The ICP-CP516 Sixteen Zone Codepad must be used 
with sixteen wireless zone systems. The sixteen zone 
codepads operation and display similarly to 8 zones 
codepads, but also display zones 9 through 16. 
Figure 4:  ICP-CP516W Sixteen Zone LED 
Codepad 
 
 
Figure 5:  ICP-CP516LW Sixteen Zone LCD 
Codepad