Raymarine Wind & Close Hauled Wind Instrument ST60 사용자 설명서
30
ST60 Wind & Close Hauled Wind Instrument Owner’s Handbook
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the
disp
and
true/app
keys
together for approximately 12 seconds, to select the Dealer calibration entry page
(see Dealer calibration diagram, sheets 1 and 2). Then momentarily press the
(see Dealer calibration diagram, sheets 1 and 2). Then momentarily press the
vmg
and
tack
keys to proceed with the calibration. As the calibration progresses,
use the
disp
key to move from screen to screen.
User calibration on/off
Use either the
vmg
or
tack
key to toggle the User calibration either on (UC1) or
off (UC0) as required.
Response settings
The response values (for wind speed, wind angle and VMG) determine the
frequency at which information is updated. A low number provides a smooth
response and a high number a much livelier response with rapid pointer
movement.
frequency at which information is updated. A low number provides a smooth
response and a high number a much livelier response with rapid pointer
movement.
Use the
vmg
(decrement) and
tack
(increment) keys to set the required value.
Response values are from 1 to 15 .
Wind speed
The Wind speed and Wind speed calibration screens are used to set the correct
value for the wind speed. On entry (from the Wind speed response screen), the
current value for apparent wind speed is displayed. Set the correct wind speed
value, by applying a calibration factor as follows:
value for the wind speed. On entry (from the Wind speed response screen), the
current value for apparent wind speed is displayed. Set the correct wind speed
value, by applying a calibration factor as follows:
1. Use the
vmg
(decrement) and
tack
(increment) keys to switch from the Wind
Speed screen to the Wind Speed Calibration screen.
2. Use the
vmg
(decrement) or
tack
(increment) key to set the wind speed cali-
bration factor to 0.7.
3. Timeout to the Wind Speed screen, and if further adjustment is necessary,
repeat steps 1 and 2.