30
ST60 Wind & Close Hauled Wind Instrument Owner’s Handbook
Dealer calibration also gives access to the Factory defaults screen. This enables 
you to re-apply the factory settings if you want to reset the instrument to a known 
operating condition.
To commence Dealer calibration, hold down the 
disp
 and 
true/app
 keys 
together for approximately 12 seconds, to select the Dealer calibration entry page 
(see Dealer calibration diagram, sheets 1 and 2). Then momentarily press the 
vmg
 and 
tack
 keys to proceed with the calibration. As the calibration progresses, 
use the 
disp
 key to move from screen to screen.
User calibration on/off
Use either the 
vmg
 or 
tack
 key to toggle the User calibration either on (UC1) or 
off (UC0) as required.
Response settings
The response values (for wind speed, wind angle and VMG) determine the 
frequency at which information is updated. A low number provides a smooth 
response and a high number a much livelier response with rapid pointer 
movement.
Use the 
vmg
 (decrement) and 
tack
 (increment) keys to set the required value. 
Response values are from  1  to  15 . 
Wind speed
The Wind speed and Wind speed calibration screens are used to set the correct 
value for the wind speed. On entry (from the Wind speed response screen), the 
current value for apparent wind speed is displayed. Set the correct wind speed 
value, by applying a calibration factor as follows:
1. Use the 
vmg
 (decrement) and 
tack
 (increment) keys to switch from the Wind 
Speed screen to the Wind Speed Calibration screen.
2. Use the 
vmg
 (decrement) or 
tack
 (increment) key to set the wind speed cali-
bration factor to 0.7.
3. Timeout to the Wind Speed screen, and if further adjustment is necessary, 
repeat steps 1 and 2.