8
INSTALLATION
C. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer
to Figure 10)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
OPTION:  To achieve a center vertical installation a 45º el-
bow and a clean-out tee can be used to offset the pipe from 
the exhaust outlet to the rear center of the stove.
OPTION: Install L-Vent elbow in place of clean-out tee. Lo-
cate stove. Drop plumb bob to center of tee outlet, mark 
point on ceiling. Install ceiling support and L-Vent pipe per 
L-Vent manufacturer’s instructions.
1.  Always maintain 3” clearance from combustible materi-
als. When passing through additional floors or ceilings, 
always install firestop spacer.
2.  After lining up for hole in roof, cut either a round or square
  hole in roof, always 3” larger all the way around pipe. 
Install  upper  edge  and  sides  of  flashing  under  roofing 
materials, nail to the roof along upper edge. Do not nail 
lower edge. Seal nail heads with non-hardening water-
proof mastic.
3.  Apply non-hardening, waterproof mastic where the storm
  collar will meet the vent and flashing. Slide storm collar 
down  until  it  sits  on  the  flashing.  Seal  and  install  cap. 
Mobile home installations must use a spark arrester.
D. VERTICALLY INTO EXISTING CHIMNEY SYSTEM
Adapters are available to adapt from 3” L-Vent to 6” or 8” 
Class-A chimney. (Figure 11a)
As an alternative, 3” or 4” L-Vent can be run inside existing 
chimney to termination. (Figure 11b)
This is the preferred method.
Follow guidelines for equivalent vent length.
 
 
 
 
FIGURE 10 
FIGURE 11a 
FIGURE 11b 
12” MINIMUM CLEARANCE
TO ROOF
VERTICAL ROOF VENT
ATTIC 
INSULATION
SHIELD
3” MINUMUM
CLEARANCES TO
COMBUSTIBLES
3” MINUMUM
CLEARANCES TO
COMBUSTIBLES
PELLET VENT TO
CHIMNEY ADAPTER
(SPV-CA)
UNIVERSAL
 CONNECTOR
PELLET
VENT
NOTE:
THIS METHOD
IS PREFERRED
EXISTING
CHIMNEY
SYSTEM
EXISTING
CHIMNEY
SYSTEM
TO
APPLIANCE
 
CLEANOUT
TEE
45 DEGREE ELBOW