INSTALLATION
COMBUSTION AIR SUPPLY
For a mobile home installation the stove must be connected to an 
outside source of combustion air. A 2” inside diameter metallic pipe, 
either flexible or rigid, may be attached to the inlet at the stove’s 
rear (refer to figure 5a.) A rodent guard (minimum ¼” wire mesh)/
wind hood must be used at the terminus (refer to figure 7). All con-
nections must be secured and airtight by either using the appropri-
ately sized hose clamp and/or UL-181-AP foil tape. 
For mobile home installations only: 2” inside diameter pipe may 
be used for the first 5 feet of combustion air supply run. From 5 to 
10 feet use 2 ¾” inside diameter pipe. No combustion air supply 
may exceed 10 feet.
Sources of Outside Combustion Air
a.      For freestanding installations
 
•  A hole in floor near stove rear terminating only in a venti
             lated crawl space.
•  A hole in the wall behind the stove.
WHEN OUTSIDE AIR IS NOT USED
If outside air is not used, it is important that combustion air is eas-
ily available to the air inlet. A closeable outside air register can 
be used in tightly insulated homes. In insert installations, flashing 
vents should not be restricted. The flashing should not necessarily 
seal the fireplace face.
VENTING
This freestanding appliance is certified for use with listed TYPE L-
Vent, 3” or 4” diameter in size. The stove was tested with Simpson 
Duravent brand. Class “A” chimney is not required. Refer to the 
instructions provided by the vent manufacturer, especially when 
passing through a wall, ceiling or roof.
This  is  a  pressurized  exhaust  system.  All  vent  connector  joints 
must be sealed with 500
O
F (260
O
C) RTV silicone sealant to ensure 
consistent  performance  and  avoid  smoke  spillage. All  horizontal 
connector joints must be sealed with UL-181-AP foil tape. We rec-
ommend  that  all  vertical  vent  connector  joints  be  secured  with  a 
minimum of 3 screws.
It is strongly recommended that you have a minimum of 6’ of ver-
tical  pipe  in  your  exhaust  system.    For  best  performance  of  the 
stove limit the number of elbows and horizontal pipe as much as 
possible.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING
SYSTEM OF THIS UNIT.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANU-
FACTURER.
21 1/2”
EXHAUST 
PIPE
AIR 
INLET
PIPE
28 1/2”
11”
6 1/2”
10 3/4”
FIGURE 5a 
5 7/8”
FIGURE 7 
24 3/4”
TRIM
COLLAR
28 1/2”
RODENT
GUARD
VENTILATED
CRAWL SPACE