CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications in 
accordance with the clearances given in FIGURES 3-5 and TABLE 1. Any reduction in clearance to combustibles may 
only be done by means approved by a regulatory authority.
NOTE:  Distance “C” on the left-hand side of your pellet stove may need to be greater than the minimum 
required clearance for suitable access to the control panel.
FIGURE 3
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
FIGURE 4
SIDEWALL CLEARANCES
CORNER INSTALLATION
FIGURE 5
ALCOVE CLEARANCES
PARALLEL 
A - Backwall to unit 
3.00 / 76mm
 
B - Sidewall to fl ue 
16.00 / 406mm
 
C - Sidewall to top edge of unit 
12.00 / 305mm
CORNER 
D - Adjacent wall to unit 
1.00 / 25.4mm
ALCOVE 
E - Alcove depth 
36.00 - 914mm 
 
F - Alcove height 
60.00 - 1520mm
TABLE 1
CLEARANCES
Installation