TC12 Installation, Commissioning & Maintenance Handbook 
normal direction loop connects (the reverse direction loop is 
onding to 
ver the handset 
ts. 
ommands CUD and UDT. Note: These functions only work if they are enabled in 
3.3.3.13  Reply bit function (GRL) 
omm nt:  
or ea
 bit in this reply byte. 
ch reply 
byte. The {function} field defines the source that sets the bit, or in 
the case of SCOOT loops a group of four bits.  
 
The various functions are as follows: 
 
0  = 
For GRL command, this indicates that the reply bit is driven directly. 
For GOL command, this indicates that the output bit is driven directly 
from the corresponding UTC control bit. 
1  =  Red Lamp Monitor group 0  - first red fail (RL1) 
2  =  Red Lamp Monitor group 0  - second red fail (RL2) 
3  =  Red Lamp Monitor group 0  - any lamp fail (LF) 
4  =  Red Lamp Monitor group 1  - first red fail 
5  =  Red Lamp Monitor group 1  - second red fail 
6  =  Red Lamp Monitor group 1  - any lamp fail 
7  =  Red Lamp Monitor group 2  - first red fail 
8  =  Red Lamp Monitor group 2  - second red fail 
9  =  Red Lamp Monitor group 2  - any lamp fail 
10  =  Red Lamp Monitor group 3  - first red fail 
11  =  Red Lamp Monitor group 3  - second red fail  
12  =  Red Lamp Monitor group 3  - any lamp fail  
   
 
33  =  Red Lamp Monitor group 4  - first red fail  
34  =  Red Lamp Monitor group 4  - second red fail  
35  =  Red Lamp Monitor group 4  - any lamp fail  
36  =  Red Lamp Monitor group 5  - first red fail  
37  =  Red Lamp Monitor group 5  - second red fail  
38  =  Red Lamp Monitor group 5  - any lamp fail  
39  =  Red Lamp Monitor group 6  - first red fail  
40  =  Red Lamp Monitor group 6  - second red fail  
41  =  Red Lamp Monitor group 6  - any lamp fail  
42  =  Red Lamp Monitor group 7  - first red fail  
43  =  Red Lamp Monitor group 7  - second red fail  
44  =  Red Lamp Monitor group 7  - any lamp fail  
   
 
connected to the next input after the normal direction loop)
 
Note.  The 32 inputs are numbered 1 to 32 in section 3.2.3.5, corresp
the associated pin on the 40 way input connector, howe
command numbers the inputs from 0 to 31, for the 32 inpu
 
The controller provides U/D for an Integral OTU. See the Controller Handset 
C
the T400’s configuration. 
 
GRL{Reply byte no.: 0 to 13} {bit no.: 0 to 7}={function: 0 to 255} (0) 
C
e
F
ch reply byte set up the function of each
This command is therefore repeated up to eight times for ea
666/HE/43100/000  
Page 91 
Issue 9