Siemens Boating Equipment M200D 사용자 설명서

다운로드
페이지 114
Installation / connection 
 
4.2 Connection 
 
M200D AS-Interface Basic 
58
 
Manual, 03/2009, A5E01668085-01 
4.2.4 
Power terminal 
Wiring X1 (power supply) and X2 (motor connection)    
The supply voltage is fed via power connector X1. 
The motor is supplied via power connector X2. 
 
 
NOTICE 
 
When inserting the pin/socket insert into the connector housing, make sure that the coding 
is positioned correctly. 
 
 
 
 
Pin 
Connector 
X1 
Socket X2 
without brake
Socket X2 
with 400 V / 
230 V AC 
brake 
Socket X2 
with 
180 V DC 
brake 
Phase L1 
L1 out 
L1 out 
L1 out 
Phase L2 
--- 
N  
--- 
Phase L3 
L3 out 
L3 out 
L3 out 
N  
--- 
Brake L1 
(switched) 
Brake L1 
(switched) "-" 
--- 
2)
 
2)
 
2)
 
--- 
--- 
Brake L3 
(direct)  
Brake L3 
(direct) "+" 
--- 
L2 out 
L2 out 
L2 out 
--- 
2)
 
2)
 
2)
 
11 
1)
 
--- 
--- 
--- 
12 
1)
 
--- 
--- 
--- 














;
;
PE 
PE 
PE 
PE 
1) 
  Connector monitoring 
2)
  Temperature sensor