Siemens Boating Equipment M200D 사용자 설명서
Technical specifications
8.3 Brake control
M200D AS-Interface Basic
Manual, 03/2009, A5E01668085-01
Manual, 03/2009, A5E01668085-01
91
Motor starter version
DSte / RSte
sDSte / sRSte
Isolation stability
Rated surge capacity U
Rated surge capacity U
imp
6 kV
Rated insulation voltage U
i
500 V
Safe isolation between main and control circuits
to IEC60947-1 Appendix N
400 V
Short-circuit protection
Instantaneous overcurrent release
Instantaneous overcurrent release
- I
e max
= 2 A
- I
e max
= 9 / 12 A
26 A
208 A
Rated ultimate short-circuit breaking capacity I
q
at 400 V
50 kA
Note
To change the direction of rotation, a mechanically-switching reversing contactor is
To change the direction of rotation, a mechanically-switching reversing contactor is
integrated in reversing starters with solid-state switching. The preferred position of this
contactor is "CW rotation". When the direction is changed to CCW rotation, the reversing
contactor is activated and, after a 150 ms delay, the electronic contacts. This delay is only
relevant (active) whenever the direction of rotation is changed.
After 1 hour (implemented time: 65 min) without a "CCW ON" command, the reversing
After 1 hour (implemented time: 65 min) without a "CCW ON" command, the reversing
contactor automatically reverts to its preferred position (CW rotation).
8.3
Brake control
Brake version
400 V AC / 230 V
180 V DC
Rated operating voltage
400 V AC
180 V DC
Continuous current
< 0.5 A
< 0.8 A
Inrush current at t < 120 ms
< 5 A
< 5 A
Switching capacity to IEC60947-5-1
- AC 15, at 400 V AC
- DC 13, at 180 V DC
0.4 A
-
-
0.8 A
Fault message with non-controlled brake
No
Protective measures
Short-circuit protection
Short-circuit protection
Yes, 1 A melting fuse
Inductive interference protection
Integrated varistors