Sears 486.24009 사용자 설명서

다운로드
페이지 12
6
FIGUre 9
DEFAULT POSITION
EXTENDED
(IF INTERFERENCE)
FIGUre 8
1/4 x 1-3/4
HEX BOLT
1/4 NYLOCK NUT
STEP 8:  (SEE FIGURE 8)
Assemble the two 
INNer hitch braces to the flow 
control mounting tube using a 1/4" x 1-3/4" hex bolt 
and a 1/4" nylock hex nut. 
tIGHteN.  
•  tIGHteN all nuts and bolts assembled up to this 
point. 
do not collapse tubes when tightening.
STEP 9:  (SEE FIGURE 9)
For most vehicles, the hitch tube assembly should be 
left in the default position. 
Attach the spreader hitch to your vehicle hitch. 
Check for interference with the spreader directly 
behind and out to both sides of the vehicle. Lift the 
spreader at each position to make sure there is no 
interference with the spreader's flow control. 
If there is interference with the rear of the vehicle, 
extend the hitch tube assembly.
FLOW
CONTROL
ARM
OFF
ON
1
2
3
4
6
7
8
9
10
5
ADJUSTABLE
STOP
(SETTING "5")
ON
OFF
0
FIGUre 10
STEP 10:  (SEE FIGURE 10)
Calibrate the flow setting.  Follow the steps in order 
below.
1.  Push flow control arm to "OFF" position.
2.  Slide flow control mounting bracket along tube 
until closure plate in bottom of hopper just closes. 
3.  Snug the 5/16" nylock hex nuts just enough to 
hold flow control mounting bracket in place. 
4.  Set adjustable stop at "5". Pull flow control arm 
against stop. Verify that closure plate has opened 
about half way.
5.  If closure plate does not open half way, adjust 
position of flow control mounting bracket until 
closure plate will open about half way at "5" 
and will still close when arm is locked in "OFF" 
position. 