Parker Hannifin 6K 사용자 설명서

다운로드
페이지 47
[ \ANI ] 
Network Analog Input Voltage Status
 
Type: 
Network; Assignment or Comparison 
Product Rev 
Syntax: 
n\mANI.i  (see example below) 
Units: 
n = network server # 
m = module #  
i = analog input # on module “m” 
Range: 
n = 1-6 
m = 0-7    
j = 1-2    
Default: 
n/a 
Response: 
n/a  
See Also: 
NTIO, \TANI, \TIO, VAR 
6K 5.3 
    
Use the 
\ANI
 operand to assign the voltage level of an OPTO22 analog input to a real variable (
VAR
), or to make a 
comparison against another value. 
Syntax: 
VARx=
n\mANI.i
 where “
n
” is the network server number of the OPTO22 unit, “
m
” is the I/O module number, 
and “
i
” is the input/channel number on the module (e.g., 
VAR3=2\1ANI.1
 assigns the voltage at analog input 1 
on module 1 of OPTO22 server 2 to 
VAR3
). The 
\ANI
 operand can also be used in a condition expression such as 
IF(2\3ANI.1>=2.0)
 or  
WAIT(2\4ANI.1<=1.5)
The controller addresses the OPTO22 I/O locations as follows: 
Each I/O bit is addressed by its location on a specific module. (NOTE: I/O points are not addressed by an absolute 
32-bit location on the OPTO22.) Digital input and output modules have four I/O points, or channels, and are numbered 
1-4. Analog input and output modules have two I/O points, or channels, and are numbered 1-2. 
 
Digital 
Input 
Module 
Input 
0
 
Input  
Input  
Input  
Digital 
Input 
Module 
Input 
1
 
Input  
Input  
Input  
Digital 
Output 
Module 
Output 
2
 
Output 
Output 
Output 
Digital 
Output 
Module 
Output 
3
 
Output 
Output 
Output 
Analog 
Output 
Module 
Output 
4
 
Output 
Analog 
Output 
Module 
Output 
5
 
Output 
Analog 
Input 
Module 
Input  
6
 
Input  
Analog 
Input 
Module 
Input  
7
 
Input  
EXAMPLE: OPTO22 is Network Server #2 
2\0IN.3 
2\3OUT.2 
2\5ANO.1 
2\7ANI.2 
 
Example: 
2NTIP2,172,54,125,34  ; Identify network server #2 as an OPTO22 unit at IP address  
; 172.54.125.34 
2NTCONN1 
; Attempt a connection to network server #2 (OPTO22 unit) 
2\6NTIO3 
; Server #2 (OPTO22), module #6 is an analog input module 
2\7NTIO3 
; Server #2 (OPTO22), module #7 is an analog input module 
WAIT(2\6ANI.1<=+1.5)  ; Wait until the voltage at analog input #1 of module #6 on  
; Server #2 (OPTO22) is less than or equal to +1.5VDC 
IF(2\7ANI.2>+2.4) 
; If the voltage at analog input #2 of module 7 on Server #2  
; (OPTO22) is greater than +2.4 VDC ... 
 
 
 
page 34