INSERT INSTALLATION 
INSERT INTO EXISTING MASONRY FIREPLACE 
 
NOTE: Follow pipe manufacturer’s instructions. 
 
1. 
Have the masonry chimney inspected by a qualified 
chimney sweep or installer to determine its structural 
integrity. 
2. 
You will need a pipe length equal to the chimney height from 
the hearth. If outside combustion air is to be used, you will 
need a pipe length equal to the chimney height plus 18 
inches 
3. 
Install a sealing cap at the top and bottom chimney 
4. 
You can install a fresh air intake as per Figure 24: 
Option A through the floor 
Option B through the back wall 
Option C through chimney top 
5. 
Attach the DuraVent adapter, a section of pipe and clean out 
tee, making sure the clean out tee is centered in the 
chimney flue area. Use RTV, metallic tape, and a minimum 
of three self-taping screws at all joint connections to ensure 
a tight seal. 
 
*Minimum fireplace opening 22”L x 15”D x 19 1/2”H 
 
Measure and build the chimney’s top sealing plate. Cut out holes for 
chimney pipe and outside air pipe (if necessary). Install and seal with 
flexible sealant to prevent water leakage. Install vent cap. 
 
FACEPLATE
 
Figure 22 
Exterior dimensions 
 
 
 
 
 
 
Figure 23 
Exhaust & air intake position 
 
 
7"
BOTTOM CHIMNEY CAP
TOP CHIMNEY CAP
VENT CAP
FLOOR
PROTECTION
FRESH AIR INTAKE
(OPTION A)
FRESH AIR INTAKE(OPTION C)
FRESH AIR INTAKE
(OPTION B)
 
 
Figure 24 
Venting & air intake setup 
 
 
 
 