Omron Healthcare VARISPEEDF7 사용자 설명서

다운로드
페이지 25
EN-18
Param-
eter 
Num-
ber
Name
Description
Initialize Data
A1-00
Language 
selection for 
Digital Opera-
tor dis-
play(JVOP-
160-OY only)
0:English
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
A1-01
Parameter 
access level
0:Monitoring only (Monitoring drive 
mode and setting A1-01 and A1-04.)
1: Used to select user parameters (Only 
parameters set in A2-01 to A2-32 can 
be read and set.)
2: Advanced
(Parameters can be read and set in 
both, quick programming mode (Q) 
and advanced programming mode 
(A).
A1-02
Control method 
selection
0:V/f control
1: V/f control with PG
2: Open loop vector control
3: Closed loop vector control
A1-03
Initialize
0:
No initializing
1110:Initializes using the user  
parameters
2220:Initializes using a two-wire 
sequence. (Initializes to the factory 
setting.)
3330: Initializes using a three-wire 
sequence.
Sequence / Reference Source
b1-01
Reference 
source selec-
tion
Sets the frequency reference input 
method.
0:Digital Operator
1: Control circuit terminal (analog input)
2: Serial communication (RS422 / 485)
3: Option Card
b1-02
RUN com-
mand source 
selection
Sets the run command input method.
0:Digital Operator
1: Control circuit terminal (digital inputs)
2: Serial communication (RS422 / 485)
3: Option Card
b1-03
Stopping 
method selec-
tion
Selects the stopping method when the 
Run signal is removed
0:Deceleration to stop
1: Coast to stop
2: DC injection to stop 
3: Coast to stop with timer (New Run 
commands are disregarded while 
coasting.)
b1-04
Prohibition of 
reverse opera-
tion
0:Reverse enabled
1: Reverse disabled
2: Output Phase Rotation (both rota-
tional directions are enabled)
3: Output Phase Rotation with Reverse 
disabled.
Acceleration / Deceleration Settings
C1-
††
Acceleration/
Deceleration 
times
Sets the time to accelerate/decelerate  
from 0 Hz to the maximum output fre-
quency.
S-Curve Settings
C2-
††
S-curve char-
acteristic time 
at acceleration 
Sets the S-curve characteristic at accel-
eration start and end. 
Motor Slip Compensation (not available in V/f with 
PG)
C3-01
Slip compensa-
tion gain
Used to improve speed accuracy
• Increase if output frequency is too low
• Decrease if output frequency is too 
high.
C3-02
Slip compensa-
tion delay time
(only available 
in V/f and OLV)
Sets the slip compensation delay time
• Increase if output frequency is not 
stable
• Decrease setting when slip compen-
sation responsiveness is low. 
Speed Control (ASR) (only available in V/f with PG 
and CLV)
C5-01
ASR propor-
tional gain 1
Sets the proportional gain of the speed 
loop (ASR)
C5-02
ASR integral 
time 1
Sets the integral time of the speed loop 
(ASR)
C5-03
ASR propor-
tional gain 2
C5-04
ASR integral 
time 2
C5-06
ASR delay time
(only CLV)
Sets the ASR filter time constant.
C5-07
ASR switching 
frequency
(only CLV)
Sets the frequency for switching 
between ASR gain 1, 2 and ASR integral 
time 1, 2
C5-08
ASR integral 
limit
(only CLV)
Sets the limit for the integral part of the 
ASR controller. 
Carrier Frequency
C6-01
Heavy/Normal 
duty selection
0:Heavy Duty
1: Normal Duty 1
2: Normal Duty 2
C6-02
Carrier fre-
quency selec-
tion
Selects the carrier frequency (factory 
setting depends on Inverter  capacity)
0: Low noise, low carrier
1:  2.0 kHz
2:  5.0 kHz
3:  8.0 kHz
4:  10.0 kHz
5:  12.5 kHz
6:  15.0 kHz
F: Programmable pattern
Speed Settings
d1-01 
to 
d1-16
Multi speed  
references 1 to 
16
Sets the multi-step speed references.
d1-17
Jog frequency 
reference
Torque Control (only available in CLV)
d5-01
Torque control 
selection
0:Speed control
1: Torque control
d5-06
Speed/torque 
control switch 
over timer
Sets the delay from inputting a “speed/
torque control change” signal (by digital 
input) until the control is acutally 
changed
V/f Pattern Settings
E1-01
Input voltage 
setting
This setting is used as a reference value 
for protection functions.
Param-
eter 
Num-
ber
Name
Description
P,I
0
E1-04
P = C5-01
I = C5-02
P = C5-03
I = C5-04
Motor 
speed (Hz)
User Parameter