Kramer Electronics Musical Instrument Revision 6 사용자 설명서

다운로드
페이지 94
KRAMER:  SIMPLE CREATIVE TECHNOLOGY 
The Triggers
 
 
 
 
   
46 
6.8.2 Digital Output 
The digital output function is defined by the pull-up setup: 
  Without Pullup: The port will act as a solid state relay (open/close functions) 
The GPI/O maximum voltage is 30V DC and the maximum current is 50mA 
  With Pullup: the port can be used as a TTL positive logic output (open: ~2.4V; 
closed:~0.2V) 
Setting the Digital Output  
Define the GPI/O in the port manager: 
 
Once defined as Digital Output, the GPI/O port will appear in Port Switch ->port list, and can be 
used like any other relay: 
 
Figure 92: The GPI/O Defined as Digital Output 
6.8.3 Analog Input 
The analog input accepts an analog signal from an auxiliary device: 
 
The pullup and threshold features are disabled. 
The trigger is activated once when the voltage is within a certain range of voltages. 
To add a GPI/O Trigger: 
1.  Click the Add GPI/O Trigger button.  
The following window appears: 
 
Figure 93: The GPI/O Trigger Properties Window 
2.  Select the trigger behavior: