VIII. GAS SUPPLY
CAUTION
DURING PRESSURE TESTING NOTE ONE OF THE FOLLOW-
ING:
1.  The  oven  and  its  individual  shutoff  valve  must  be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressure in
excess of 3.45 kPa.
2. The oven must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during  any  pressure  testing  of  the  gas  supply  piping
system at test pressure equal to or less than 3.45 kPa.
3. If incoming pressure is over 50mbar, a separate regu-
lator MUST be installed in the line BEFORE the individual
shutoff valve for the oven.
WARNING: 
To prevent damage to the control valve regu-
lator during initial turn- on of gas, it is very important to
open the manual shutoff valve very slowly.
After the initial gas turn-on, the manual shutoff valve must
remain open except during pressure testing as outlined
in the above steps or when necessary during service
maintenance.
Figure 2-14 - Utility Connection Locations
Electrical
Junction Box
Gas  ovens:
19mm pipe for
gas  utility  connection
Electric  ovens:
Cutout  for  electrical
connection
VII. ELECTRICAL SUPPLY
WARNING
Authorized supplier personnel normally accomplish
the connections for the ventilation system, electric supply,
and gas supply, as arranged by the customer.  Following
these  connections,  the  factory-authorized  installer  can
perform the initial startup of the oven.
NOTE:  
All  aspects  of  the  electrical  supply  connection  must
comply  with  current  IEC/CEE  requirements  and  with  all
applicable  local,  national,  and  international  codes.
Check the oven serial plate before making any electric supply
connections. Electric supply connections must agree with data
on the oven serial plate.  The location of the serial plate is shown
in Figure 1-1 (in Section 1, Description).
A fused disconnect switch or a main circuit breaker (customer
furnished) MUST be installed in the electric supply line for each
oven  cavity.    The  circuit  breaker/disconnect  must  have  3mm
contact gaps breaking all poles of the supply.  It is recommended
that this circuit breaker/disconnect have lockout/tagout capability.
The  supply  conductors  are  to  be  90°C-rated  copper  wiring.
Additional wiring information is shown on the wiring diagrams
in Section 5, Electrical Wiring Diagrams and inside the machin-
ery compartment of the oven.
The  oven  requires  a  ground  connection  to  the  oven  ground
screw located in the electrical junction box.  (The box is shown
in  Figure  2-14.)    The  ground  connection  must  comply  with
current  IEC/CEE  requirements  and  with  all  applicable  local,
national,  and  international  codes.    If  necessary,  have  the
electrician  supply  the  ground  wire.    Do  NOT  use  the  wiring
conduit or other piping for ground connections!
A. Additional Information - Gas Ovens
All  electric  supply  connections  are  made  via  the  electrical
junction box on the rear of the oven, shown in Figure 2-14.  The
power  lines  then  connect  to  the  oven  circuits  through  safety
switches located inside the machinery compartment and each
blower motor compartment.  These switches interrupt electric
power to the oven when the Machinery Compartment Access
Panel is opened, OR when either of the blower or rear shrouds
is  removed.
B. Additional Information - Electric Ovens
A cutout in the back wall of the machinery compartment provides
access to the electrical supply connections.  See Figure 2-14.
The actual wiring connections are made at the electrical junction
box.
C. Connection
Refer to the wiring diagram inside the machinery compartment,
or  in  Section  5  of  this  Manual,  to  determine  the  correct
connections for the electrical supply lines.  Connect the supply
as indicated on the wiring diagram.
If required by national or local codes, connect an equipotential
ground wire to the lug next to the   symbol.  The equipotential
ground  connection  must  meet  all  applicable  national  and  lo-
cal  code  requirements.
SECTION 2 - INSTALLATION