Middleby Marshall PS360-U 사용자 설명서

다운로드
페이지 24
12
ENGLISH
Figure 2-16 - Gas Burner and Piping Assembly
Multifunction
Gas Valve
A. Gas Utility Rough-In Recommendations
The  following  gas  system  specifications  are  STRONGLY
RECOMMENDED.    Deviating  from  these  recommendations
may affect the baking performance of the oven.
Gas Meter
•
One or two oven cavities:  354 
l
/sec meter
•
Three or four oven cavities:  566 
l
/sec meter
Gas Line
•
DEDICATED LINE from the gas meter to the oven
•
50.8mm pipe for natural gas
•
38.1mm  pipe  for  propane
•
Maximum length:  61m.  Each 90° elbow equals 2.13m of
pipe.
B. Connection
WARNING
Some procedures in this section may require conver-
sions, readjustments, or service on the oven's gas system.
Before performing these procedures, check that the main
gas supply valve and the circuit breaker/fused disconnect
are in the OFF ("O") position.  After completing these proce-
dures, perform a gas leak test before operating the oven.
CAUTION
The terms of the oven's warranty require all start-ups, conver-
sions and service work to be performed by a Middleby Marshall
Authorized Service Agent.  The installation, start-up and changes
required when changing from one gas type to another can be
performed ONLY by a certified professional.
NOTE:  The  gas  supply  connection  should  be  according  to
applicable ISO 228-1 or ISO 7-1 recommendations.  All aspects
of the gas supply connection must comply with current IEC/CEE
requirements and with all applicable local, national, and inter-
national  codes.
Check the oven’s gas supply requirements before making the
gas utility connection.  Gas supply requirements are listed on
the oven’s serial plate.
Check the serial plate to determine the type of gas to be used
with the oven.  Check that the gas type indicated matches the
local supply at the installation.  If the gas type on the serial plate
does NOT match the local supply, directions for converting the
oven for use with other gases are described in Preparation for
Use with Various Gases, in this section.
Refer to the instructions in the gas hose package (included in
the Installation Kit) before connecting the gas line.  One gas line
connection  method  is  shown  in  Figure  2-15;  however,
compliance  with  the  applicable  standards  and  regulations  is
mandatory.
Orifice
(manifold)
pressure tap
Governor
disabled  for
liquid
propane  (LP)
operation
Governor
enabled  for
natural gas
operation
Pilot pressure tap
Low Flame
Bypass  Line
High Flame
Solenoid Valve
Gas Burner
Burner Blower
Supply (inlet)
pressure tap
Union
Pilot Line
Multifunction Gas Valve
Figure 2-15 - Flexible Gas Hose Installation
Appliance
Connection/Male
Nipple
Flexible
Gas Hose
Full-Flow Gas
Shutoff  Valve
To Gas
Supply Pipe
90°
Elbow
SECTION 2 - INSTALLATION