Meridian Data Excel / Meridian Data Computer Drive 1 사용자 설명서

다운로드
페이지 139
S
ECUR
S
TOR 
A
STRA 
ES      
                        
        
133
 
Physical Drive Failed 
When physical drive status shows failed, the physical drive cannot be repaired. You must replace the failed drive.  
Physical Drive Fails during Migration 
Astra ES has two methods for migrating a disk array: 
• 
DDF 
– The default setting. Slower but reliable  
• 
NVRAM 
– An optional setting that requires special access. Faster but risks data loss  
Normally, RAID level migration is done under the default Disk Data Format (DDF) setting. If a physical drive or 
the controller fails during migration, the disk array goes critical, and you can rebuild it. Migration under DDF can 
take up to several hours depending on the number and size of the physical drives and data input/output activity. 
You can set the Astra ES to migrate disk arrays under Non-Volatile Random Access Memory (NVRAM), a much 
faster process because it writes data to the memory in the controller. However, if a physical drive or the controller 
fails during migration, the logical drives will go offline and you will lose data.  
Because the setting for migration under NVRAM requires special access, most users will not encounter this 
condition. 
Physical Drive Fails during Transport 
Transport is the action of moving the physical drives of a disk array: 
• 
To different slots in the same Astra ES enclosure  
• 
From one Astra ES enclosure to another  
If a physical drive fails during a transport, or you do not move all of the physical drives to their new locations, 
Astra Web GUI will display an incomplete array.