Power Supplies 
 
Astra ES are equipped with redundant power supplies. The 
advantage of dual power supplies is that, should one fail, the 
other will continue powering the subsystem until the faulty one 
can be replaced. Astra ES is capable of operating on a single 
power supply. As a result, if one power supply fails you must 
watch the front panel LEDs or Astra Web GUI in order to 
become aware of the condition. 
The power supplies are hot-swappable, meaning you can leave 
the Astra ES running when you replace the bad one. Be careful, 
however, to remove the faulty power supply and not the good 
one, or Astra ES will come to an immediate stop and your data 
will be unavailable until the system is powered and booted 
again.  
As noted above, if a power supply fan fails, you must replace the 
power supply. Without the fan to cool it, the power supply will 
overheat and eventually fail anyway.  
No tools are required for the procedure.  
 Battery 
 
Astra ES uses a battery as backup power for the cache. Should 
a power failure occur, the battery enables the cache to hold data 
up to 60 hours. The battery recharges during normal Astra ES 
operation.  
In most cases, installing a replacement battery will correct a 
marginal or failed condition. The battery is located in the cooling 
unit above the controller. Remove the cooling unit for access. 
The battery is hot-swappable. 