Common problems and solutions      79
IRQ conflicts
In general, PCI devices can share an interrupt line (IRQ). 
However, sometimes this might not be possible; for example, 
complex PCI devices, or bus master devices should not share 
an IRQ. The types of difficulties that you might run into are as 
follows:
IRQ conflict under Windows NT 4.0
In the event that your Matrox imaging board(s) cannot share 
an IRQ line with other devices, allocate a different IRQ to 
each device in the IRQ Configuration Setup section of the 
BIOS Setup Program, if possible (accessible on bootup).
IRQ conflict under Windows 98
To resolve this problem with the PCI and CompactPCI form 
factors, either re-assign a different IRQ line to the PCI slot 
in which the Matrox Meteor-II board is installed or change 
the resource settings in the Windows’ Device Manager 
property page. This page can be accessed using the System 
utility in the Control Panel.
To resolve this problem with the PC/104-Plus form factor, 
change the rotary switch settings. 
Note that PCI devices cannot share interrupt lines with EISA 
or ISA devices. 
Other possible solutions to the above problems:
Move the Matrox Meteor-II board to another (free) PCI slot.
Swap Matrox Meteor-II with another board.
Problems during application development
Computer ‘hangs’ or produces unwanted results while an 
application is running
Sometimes, an EISA or ISA device might attempt to use the 
same interrupt, registers, or memory space as PCI boards, and 
this causes a conflict. Check for an interrupt, memory, or 
register conflict: