System Requirements
A safe, well designed voltage isolation system should 
have the following features:
All components of the isolation system that are 
charged to high voltage must be contained within an 
enclosure that prohibits persons from making con-
tact with the high voltage components before the 
system voltage is discharged.
A bleed resistor to drain off the system voltage when 
the spray gun is not in use.
The system should not have any severe arcing 
occurring when the isolation mechanism opens and 
closes. Severe arcing will shorten the life of the sys-
tem components.
The system must include a means for automatically 
discharging the system voltage when anyone opens 
the isolation enclosure.
Warning Sign 
Mount the warning sign, Part No. 186118, in the spray 
area where it can be seen and read by all operators. 
Additional warning signs are available at no charge.
Install the System
. 2. on page 10 shows a PRO Xs electrostatic water-
borne air spray system. For assistance in designing a 
system to suit your particular needs, contact your Graco 
distributor.
CAUTION
The Graco warranty is void if the spray gun is con-
nected to a non-Graco voltage isolation system or if 
the gun is operated above 60 kV.
WARNING
Fire, Explosion, and Electric Shock Hazard
Installing and servicing this equipment 
requires access to parts which may cause 
electric shock or other serious injury if work 
is not performed properly.
• Do not install or service this equipment 
unless you are trained and qualified. 
• Be sure your installation complies with all 
National, State and Local safety and fire 
codes, NFPA 33, NEC 504 and 516, and 
OSHA standard 1910.107.