Fill-rite Water Pump FR405 사용자 설명서

다운로드
페이지 10
2
•1" polypropylene ball valve/nozzle
•Buna-N or EPDM hose
•Telescoping steel suction tube
• 820 electronic digital meter (for thin or thick
viscosities)
•2" NPT or 2" buttress inlet bung adapter
•1" FNPT straight and 90
o
 inlet/outlet fittings available
•Wraparound tubular mounting frame
•Santoprene diaphragms
•12 VDC, 24 VDC, 115 VAC/60 Hz, 230 VAC/50 Hz
available
Design Features
•1" FNPT straight inlet and 90
o
 outlet standard
•15 PSIG maximum outlet pressure
•2600 RPM, 1/4 HP motor:
•12 VDC, rated at 20 amps
•24 VDC, rated at 10amps
•115 VAC/60 Hz rated at 2.0 amps
•230 VAC/50 Hz rated at 1.1 amps
•Thermal overload protection of the motor
•Positive displacement/self-priming design
•Unaffected by particulate materials up to 0.100"
diameter in the pumped fluids
•Flow easily controlled by outlet throttling from
maximum to zero
•Pump may run dry without damage
•Handles viscosities from 1.0 CPS to 3000 CPS
(SAE 140 gear oil at 68
o
F)
•Minimum shear (agitation) of pumped fluids
•Does not include inlet strainer
•Minimum operating temperature: -10ºF  (-23ºC)
•Maximum operating temperature: 130ºF  (54ºC)
•Overall dimensions: 14" (35.6 cm) long x 8.25" (21cm)
high x 8.75" (22.2 cm) deep
•30 minute duty cycle, not for continuous operation
Fluid Compatibility
The FR400 Series pump is compatible with the following fluids:
Ethylene Glycol, Hydraulic Oil,  Motor Oil, Water
The FR400 Series pump is NOT
NOT
NOT
NOT
NOT compatible with the following
fluids:
Acetone, Ammonia, Gasoline, Bleach, Chlorine, Hydro-
chloric Acid, Ink, MEK
If in doubt about compatibility of a specific fluid, contact the
supplier of the fluid to check for any adverse reactions to the
wetted materials shown in the parts list.
TECHNICAL INFORMATION
OPTIONS
GENERAL DESCRIPTION
SAFETY  INSTRUCTIONS
1. Use Teflon® tape to seal all joints to avoid leakage
of fluids being pumped.  Leaking of caustic and/or hazardous
fluids could result in severe injuries.
2. Never disassemble YOKE ASSEMBLY (see item 12).
This is under extreme pressure and injury could result.
3. Tank or barrel should be anchored to prevent tipping in
both the full and empty conditions.
4. The pump motor is equipped with thermal overload pro-
tection. If overheated, it will shut itself off without any
damage to the windings. Be sure to turn off the pump
power if this occurs. As the motor cools, it will start without
warning if power is on.
DANGER
EXPLOSION PROOF MOTOR
OPTION:  Electrical wiring
should be done by a licensed
electrician in accordance
with approved electrical
codes. Motor should be prop-
erly grounded and a rigid con-
duit should be used when in-
stalling electrical wiring. Im-
proper use or installation of
this product can cause seri-
ous bodily injury or death.
DANGER
Not for use with fluids that
Not for use with fluids that
Not for use with fluids that
Not for use with fluids that
Not for use with fluids that
have a flash point below 100°F
have a flash point below 100°F
have a flash point below 100°F
have a flash point below 100°F
have a flash point below 100°F
(37.8°C, ie: gasoline, alcohol).
(37.8°C, ie: gasoline, alcohol).
(37.8°C, ie: gasoline, alcohol).
(37.8°C, ie: gasoline, alcohol).
(37.8°C, ie: gasoline, alcohol).
Refer to NFPA 325M (Fire
Refer to NFPA 325M (Fire
Refer to NFPA 325M (Fire
Refer to NFPA 325M (Fire
Refer to NFPA 325M (Fire
Hazard Properties of Flam-
Hazard Properties of Flam-
Hazard Properties of Flam-
Hazard Properties of Flam-
Hazard Properties of Flam-
mable Liquids, Gases, and
mable Liquids, Gases, and
mable Liquids, Gases, and
mable Liquids, Gases, and
mable Liquids, Gases, and
Volatile Solids) for flash
Volatile Solids) for flash
Volatile Solids) for flash
Volatile Solids) for flash
Volatile Solids) for flash
points of common liquids.
points of common liquids.
points of common liquids.
points of common liquids.
points of common liquids.
Static electricity buildup and
Static electricity buildup and
Static electricity buildup and
Static electricity buildup and
Static electricity buildup and
discharge could result in arc
discharge could result in arc
discharge could result in arc
discharge could result in arc
discharge could result in arc
and explosion.
and explosion.
and explosion.
and explosion.
and explosion.
WARNING
This pump  should not be used to fuel aircraft.  This pump
is not suited for use with fluids for human consumption.
The Fill-Rite Series FR400 is a double action diaphragm pump,
using a patented, spring-driven, positive displacement
mechanism.  The flow rate with low viscosity material  is up to
13 GPM/49 LPM. The ultimate in chemical handling capability
is provided with stainless steel, polypropylene, polyester and
fluorocarbon wetted parts.
 Fluorocarbon
Polypropylene
 FilCon
TM 
                                               Stainless Steel
 Buna-N