Antunes, AJ VCT-50 사용자 설명서

다운로드
페이지 28
VERTICAL CONTACT TOASTER
12
P/N 1010729 Rev. C 05/04
VERTICAL CONTACT TOASTER
13
P/N 1010729 Rev. C 05/04
   4.  Make sure the spacers are placed inside the 
tensioner arm.  The spacers are smaller than the 
holes to allow the tensioner to pivot freely.
Replacing Conveyor Motor and Fan Blade
NOTE: A small amount of Loctite (Blue & Red) is 
required for proper gear motor installation.
   1.  Remove control cover.
   2.  Disconnect the motor wires and remove the 
drive motor and drive motor bracket (Figure 
10).  Discard the 8-32 x 5/16” mounting bracket 
screws.
   3.  Remove the motor sprocket using a hex wrench.
   4.  Remove the drive motor bracket from the gear 
motor.  Save the four 10-32 x 3/8” pan head 
screws (P/N 310P154).
   5.  Place one drop of Loctite (Blue) into each thread-
ed hole in the gear reducer casting.  Attach the 
drive motor bracket to the gear reducer using 
the original four 10-32 x 3/8” screws (310P154) 
removed in step 3.
   6.  Attach the motor sprocket to the gear reducer as 
shown in Figure 10.
NOTE: Be sure sprocket setscrew is positioned 
on the flat of the gear reducer shaft.  Maintain the 
3/16” dimension as shown in Figure 11.  Apply 
Loctite (Blue) to threads of setscrew and tighten 
securely.
   7.  Using the four new 8-32 x 5/16” stainless steel 
SEMS truss head screws (P/N 308P151), attach 
the drive motor bracket to the mounting bracket.  
DO NOT tighten screws at this time.
   8.  Place the drive chain on the sprocket and push 
down on motor.  Allow 1/4” (0.6 mm) play at mid-
dle of drive chain, then tighten mounting screws 
while holding motor.  Check drive chain play after 
tightening screws.
   9.  Re-connect motor wires, one at a time.
 10.  Re-install control cover.
Apply only 1 drop of Loctite (RED) to front of fan assy. after 
assembly.  Outer edge of fan blade hub to be flush with end of 
motor shaft.
3/16”
(4.75 mm)
Apply Loctite (BLUE) on setscrew of sprocket and all other 
mounting screws.
Figure 11. Replacing Drive Motor and Fan Blade
Figure 10. Replacing Drive Motor and Fan Blade
POWER
TEMP
DOWN
TEMP
UP
TEMP
SCALE
˚C
˚F
Fan Blade
Motor Sprocket
Drive Motor/Gear Reducer -  Place 1 drop of 
Loctite (Blue) into each threaded mounting 
hole of reducer before installing.
Drive Motor 
Bracket
Mounting 
Bracket Screw
(308P151)
Motor Mounting 
Screw (310P154)
Mounting 
Bracket
MAINTENANCE (continued)