technical theory of Operation
When the Rocker switch (power On/Off) is ON, line 
voltage flows to the primary side of the step down 
transformer.  the transformer’s secondary side supplies 
12 and 24 Vac to the control board.  
Once powered, and provided that the generator’s tem-
perature is below the setpoint temperature, the control 
board calls for heat by supplying 3 to 5 VDc to the 
solid state Relay terminals 3 (+) 4 (-).  Once powered, 
the solid state Relay then closes terminals 1 and 2, 
which allows line voltage to flow to the generator. 
as the generator begins to heat up, a type “K” thermo-
couple monitors the internal generator temperature.  as 
the heat continues to increase, so does the thermocou-
ple’s Dc millivolts. 
Once  the generator’s temperature approaches the set-
point temperature, the control board begins to pulse 
the VDc to the solid state Relay.  the generator’s Vac 
and aMPs will also pulse during this point.  When the 
generator’s temperature is between the recommended 
setpoints of 375 - 400° f (190 - 204° c), the thermo-
couple generates approximately 7.5 - 8.5 Dc millivolts.  
the control board receives these millivolts and pro-
ceeds to remove the 3-5 VDc to the solid state Relay 
since the heating circuit has now become satisfied.
then, the solid state Relay terminals 1 and 2 open up, 
and the generator stops heating.  the heating circuit 
cycles on and off as needed, even at idle.  
When the single shot button is pushed, it signals the 
control board to initiate a single shot of steam.  the 
control board then supplies 24 Vac to the solenoid 
Valve for a split second.  the solenoid Valve opens and 
allows approximately 3/4 - 1 ounce (4 to 5 tablespoons) 
of water to be disbursed onto the generator surface 
for steaming. the water is immediately converted into 
steam, which is forced up through the black Manifold 
Orifices to steam the product within the baskets.  
each of the four channel buttons can be custom pro-
grammed for cycle time, time between when each 
steam shot occurs, and water volume used per each 
shot (see the Programming section of this manual). an 
audio signal will sound for three seconds at the end of 
the cycle.  
two safety devices are incorporated into the Vs-350:
 
•  Hi-Limit thermostat 
 
•  Pressure Relief Plunger
if the heating circuit continues to call for heat and the 
generator overheats, a manual resettable Hi-Limit 
thermostat will trip and open the generator circuit.  
if water and or steam pressure builds up beneath the 
black Manifold Plate (due to restricted Manifold Plate 
orifices), a Pressure Relief Plunger will elevate and vent 
the steam pressure above the manifold plate.
nOte: If any of these conditions should arise, the 
root cause must be determined and corrected.  see 
the maintenance section of this manual for further 
details.
nOte: all direct water fed units require a water 
pressure regulator.  It should be set to 20-25 psi 
(1.4-1.7 kg/cm2 or 138-172 kpa).  failure to install a 
water pressure regulator will result in poor steam-
ing and flooding of the steam generator.
maIntenance (continued)