trOUblesHOOtInG
warnInG
to avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel.  the unit should be unplugged when servicing, 
except when electrical tests are required.  
problem
possible cause
corrective action
Rocker switch (power 
On/Off) is turned on but 
the switch indicator Light 
is still off and the control 
Panel is blank
Power cord not correctly plugged in.
Plug in the power cord correctly.
the power cord and/or electrical plug 
is damaged.
inspect electrical wire, plug, and receptacle.
the main electrical panel circuit break-
er is off or has been tripped.
Reset circuit breaker.  contact your mainte-
nance person or authorized service agency if 
it trips again.
Rocker switch is inoperable.
contact your maintenance person or 
authorized service agency for service.
the unit’s main electri-
cal panel circuit breaker 
trips.
Damaged receptacle, plug, or cord; a 
loose connection or an internal compo-
nent failure.
turn the unit off, allow it to cool to room tem-
perature, and then restart the unit.
Power On/Off switch and 
indicator are on but the 
display is blank.
control board is inoperable.
contact your maintenance person or 
authorized service agency for service.
transformer is inoperable.
Loose or burnt wiring in heating circuit.
Power On/Off switch is 
turned on, the switch 
indicator light is on, the 
control panel display is 
on, but the unit is not 
heating up.
Heat Relay is inoperable.
Reset the Hi-Limit thermostat according to 
the Operations section of this manual.  if the 
Hi-Limit thermostat requries continuous reset-
ting, contact your maintenance person or 
authorized service agency for service.
Hi-Limit thermostat is tripped.
thermocouple is inoperable.
control board is inoperable.
steam generator is inoperable.
Loose or burnt wiring in heating circuit.
unit heats but there is lit-
tle or no steam produced
and/or
the product requires 
more steaming than 
usual.
Water Line Valve is closed.
check that the Water Line Valve is open.
filter strainer is restricted.
check and clean the filter strainer as 
described in the Maintenance section of this 
manual.
Quick Disconnect is not fully engaged 
at rear of the unit or is damaged.
Remove and reengage the Quick Disconnect 
firmly until a “click” is heard.  Replace if dam-
aged.
Low or no water pressure in water line. Remove the Quick Disconnect insert from the 
rear of the unit.  While holding into an empty 
cup, press the white plastic tip.  strong steady 
water flow should be noted. if so, re-engage 
firmly into unit.  if not present, or pressure 
is low, contact your maintenance person or 
plumber.
spray tube is restricted.
Remove and clean spray tube as described 
in the Maintenance section of this manual.
black Manifold orifices are restricted.
Remove and clean the black Manifold as 
described in the Maintenance section of this 
manual.
unit is not being cleaned daily or prop-
erly.
clean unit daily as described in the 
Maintenance section of this manual.