ADIC SNC 5100 사용자 설명서

다운로드
페이지 228
SNC 5100 
50
SCSI Channel MAP
6-00020-02
If all of the attached SCSI devices are not displayed, go to “SCSI Channel 
MAP” on page 50.
Check Channel Zoning Settings
Step 1.
Enter the 
fcShowDevs
 command from the service terminal. 
For more information, see the 
Look at the display for each Fibre Channel interface. If all of the 
SCSI devices are displayed under each Fibre Channel interface, 
then host access to SCSI devices is not being restricted by Channel 
Zoning.
Step 2.
Use the ADIC Management Console to change Channel Zoning 
settings. 
For information on Channel Zoning, see the ADIC Management 
Console User Guide
.
SCSI Channel MAP
Perform these steps if:
• Errors are reported on the SCSI bus
• SCSI I/O fails to operate
• Parity errors are detected on the SCSI bus
• SCSI device reports unit attention on non-removable device
• Unexpected SCSI bus reset occurs
• Unexpected SCSI disconnect reported by a SCSI device
Get  SCSI Information for the SNC 5100
Step 1.
Connect a service terminal to the SNC 5100.