Design Dynamics DVF-36S-N 사용자 설명서

다운로드
페이지 36
www.desatech.com
120441-01A
22
6.  Wait five (5) minutes to clear out any 
gas. Then smell for gas, including near 
the floor. If you smell gas, STOP! Fol-
low  “B”  in  the  safety  information  on 
page 21. If you don't smell gas, go to 
the next step.
7.  Turn the equipment shutoff valve coun-
terclockwise 
 to the ON position. 
Do not force.
8.  Replace center brick/control cover.
9.  Turn on all electric power to appliance.
10. Turn wall switch to the ON position.
11. Visually  locate  pilot.  Ignitor  should 
begin to spark and main burner should 
ignite once flame appears at pilot.
• If lighting appliance for the first time 
each season, it may take several at-
tempts before supply gas can reach 
pilot and main burners.
• If appliance will not stay lit after several 
attempts, follow instructions under To 
Turn Off Gas To Appliance
 and call your 
service technician or gas supplier.
TO TURN OFF GAS 
TO AppLIANCE
1.  Turn off the wall switch.
2.  Turn off all electric power to the appli-
ance if service is to be performed.
3.  Remove center brick/control cover.
4.  Turn  equipment  shutoff  valve  clock-
wise 
 to OFF. Do not force.
5.  Replace center brick/control cover.
Figure 34 - Turning Equipment Shutoff 
Valve to the OFF Position
Equipment 
Shutoff Valve
Pilot Adjustment 
Screw
Sensing 
Rod
Pilot 
Burner
Ignitor
Figure 35 - Pilot
REMOTE  
OpERATION
1.  Turn equipment shutoff valve to ON posi-
tion. You can now turn the burner on and 
off with hand-held remote control unit. 
 
IMPORTANT: Be sure to press ON/OFF 
buttons on hand-held remote control 
unit  for  up  to  3  seconds  to  assure 
proper operation.
2.  Press ON/OFF button to turn burner on 
and off.
inSPectinG BUrnerS
Check  pilot  flame  pattern  and  burner  flame 
patterns often.
PILOT ASSEMBLY
The  pilot  assembly  is  factory  preset  for  the 
proper flame. Alterations may have occurred 
during  shipping  and  handling.  The  pilot  is 
located on the right hand side of the burner.
The flame must envelope 1/4" of top of the 
ignitor/sensor and grounding stem. 
If  your  pilot  assembly  does  not  meet  these 
requirements:
•  Turn the adjustment screw marked PILOT 
clockwise to decrease or counterclockwise 
to  increase  the  flame  to  proper  size  (see 
Figure 34). Do not remove the adjustment 
screw.
•  see Troubleshooting, page 25
OPerAtiOn
Continued
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or float-
ing. Flame patterns will be different from unit 
to unit and will vary depending on installation 
type and weather conditions.
If the vent configuration is installed incorrectly, 
the flames will lift or "ghost". This can be dan-
gerous. Inspect the flames after installation to 
ensure proper installation and performance. 
Pilot 
Burner
Ignitor/
Sensor
Figure 36 - Correct Pilot Flame Pattern
Sensing 
Rod