Design Dynamics DVF-36S-N 사용자 설명서

다운로드
페이지 36
www.desatech.com
120441-01A
24
 WARNING: Do not operate fire-
place with glass door unlatched, 
removed, cracked or broken. 
PILOT AND BURNERS
•  Remove material before cleaning burners 
and replace when cleaning is complete.
•  Burner  and  controls  should  be  cleaned 
with  compressed  air  to  remove  dust,  dirt 
or lint.
•  Use a vacuum cleaner or small, soft bristled 
brush to remove excess dust, dirt or lint.
LOGS
•  Use  a  vacuum  cleaner  to  remove  any 
carbon buildup on logs.
•  Replace material periodically as needed. 
See Replacement Parts.
VENTING SYSTEM
Conduct  annual  inspection  of  the  venting 
system following these guidelines:
1.  Check areas of venting system that are 
exposed to the weather for corrosion (rust 
spots or streaks and, in extreme cases, 
holes).  Have  these  items  replaced  im-
mediately by a qualified service person.
2.  Remove the vent cap and shine a flash-
light  into  the  vent.  Remove  any  foreign 
material.
3.  Check  for  evidence  of  excessive  con-
densation. Continuous condensation can 
cause corrosion of caps, pipes and fittings 
and can be caused by having excessive 
lateral runs, too many elbows or exterior 
portions of the system being exposed to 
cold weather.
4.  Inspect joints to verify that no pipe section 
or  fitting  has  been  disturbed  and  loos-
ened. Check mechanical supports such 
as wall straps for rigidity.
technicAL Service
You may have further questions about instal-
lation,  operation  or  troubleshooting.  If  so, 
contact  DESA’s  Customer  Service  Depart-
ment at 1-866-672-6040. When calling, please 
have your model and serial numbers of your 
heater ready.
You can also visit DESA’s technical service 
web site at www.desatech.com.
cLeAninG AnD 
MAintenAnce
Continued
SPeciFicAtiOnS
DVF-36S-N, DVF-36H-N, DVF-36SC-N, 
DVF-36HC-N
•  Rating: 66,000 Btu/hr
•  Gas Type: Natural Gas Only
•  Ignition: Electronic
•  Manifold Pressure: 3.5" w.c.
•  Minimum Inlet Supply Pressure: 7.0" w.c.
DVF-36S-P, DVF-36H_P, DVF-36SC-P, 
DVF-36SH-P
•  Rating: 62,000 Btu/hr
•  Gas Type: Propane/LP Gas Only
•  Ignition: Electronic
•  Manifold Pressure: 10.0" w.c.
•  Minimum Inlet Supply Pressure: 11.0" w.c.
rePLAceMent PArtS
Note:  Use  only  original  replacement  parts. 
This will protect your warranty coverage for 
parts replaced under warranty. 
pARTS UNDER WARRANTY
Contact authorized retailers of this product. 
If  they  can  not  supply  original  replacement 
part(s), call DESA’s Customer Service Depart-
ment at 1-866-672-6040.
When calling DESA, have ready
•  your name
•  your address
•  model  and  serial  numbers  of  your  fire-
place 
•  how fireplace was malfunctioning
•  type  of  gas  used  (propane/LP  or  natural 
gas)
•  purchase date
Usually, we will ask you to return the part to 
the factory.
pARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. 
If  they  can  not  supply  original  replacement 
part(s),  call  DESA  at  1-866-672-6040  for 
referral information.
When calling DESA, have ready
•  model number of your fireplace 
•  the replacement part number
Service hintS
When Gas pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  fireplace will not produce specified heat
•  propane/LP gas supply might be low (pro-
pane/LP units only)
You may feel your gas pressure is too low. If 
so, contact your local gas supplier.