DS72 HOST MODULE OWNER’S MANUAL
DS72 QUICK START
3
DS72 QUICK START
This section describes the basic steps required to set up and configure your DS72.  If you need to
acquaint yourself further with the setup, configuration, and operations, see “Detailed Operations and
Configuration” beginning on page 8.
GETTING STARTED
Before the DS72 can be used within a network, there are a few parameters which must be configured.
For an initial setup, connect the serial port of your computer to the RJ-45 port labeled “EIA-232” on the
DS72 module using the 9FRJ45PC-4 adapter and the RJ08X007 (8 pin crossed) cable.
With standard serial communications software or a terminal, set serial communications parameters to
9600 bps, 8 data bits, 1 stop bit, and no parity. This will allow direct communications with the DS72
module. Apply power to the DS-Series unit. The following main menu will appear:
Data Switch Series - F.1.00
Bay Technical Associates
Unit ID: BAYTECH DS72
Port Select Code: $BT
Attention Character: ;
Device A        (2,1)...........1
Device B        (2,2)...........2
Device C        (2,3)...........3
Device D        (2,4)...........4
DS-RPC          (3,1)...........5 (if connected in a DS-RPC unit)
Configure.......................C
Status..........................S
I/O Modules Reset...............RM
Unit Reset......................RU
Exit............................X
Logout..........................T
Enter Request :
NOTE:  Depending on the DS series or DS-RPC model, the menus may vary according to the
number of DS74 modules installed in the unit.
At a minimum, the IP Address, Subnet Mask and Gateway must be programmed in order to access the
unit via your network. At the “Enter Request:” prompt, type “C” followed by <cr>. The following menu
is displayed: