Watts Radiant Water System R13 사용자 설명서

다운로드
페이지 16
 
 
 
VI.  APPENDIX 
 
The following tables are intended as a guide to determining the flow rates for the R13 
series RO systems.  All flows are in gallons per hour (GPH). 
 
Nominal flows for systems operating at 50% recovery. 
 
 
R12-0250 R12-0600 R12-1200 
Product GPH 
10.4 
25 
50 
Reject  GPH 
10.4 
25 
50 
 
Temperature Correction Factors 
 
Deg C 
Deg F 
Correction Factor 
25 77 
1.00 
24 75.2 
0.97 
23 73.4 
0.94 
22 71.6 
0.92 
21 69.8 
0.89 
20 68 
0.86 
19 66.2 
0.84 
18 64.4 
0.81 
17 62.6 
0.79 
16 60.8 
0.77 
15 59 
0.74 
14 57.2 
0.72 
13 55.4 
0.70 
12 53.6 
0.68 
11 51.8 
0.66 
10 50 
0.64 
9 48.2 
0.62 
8 46.4 
0.61 
7 44.6 
0.59 
6 42.8 
0.57 
5 41 
0.55 
 
 
Multiply the nominal product flow at 25° C by the temperature correction factor to determine the 
flow at various other temperatures.