ERROR ITEMS AND DIAGNOSTIC CODES
When an error occurs, the dryer will sound an error tone for 5 seconds and show one of the 
following Error Codes in its display continuously.
Error Display
Trigger
Action Taken
tE
The Thermistor resistance is 
very low or high.
Check for: 
- Clogged lint screen. 
- Restricted vent system. 
- Check Thermistor resistance.
dE
Dryer running with door open.
Check for: 
- Close the door and run the dryer. 
- Check for loose or open wire terminals in
  Door Sensing circuit.
dF
Invalid door condition.
Check for: 
- Loose or open wire terminals in Door 
Sense circuit.
bE2
Key on display panel in invalid 
state.
Check for: 
- Check if display PCB circuit has short.
FE
Invalid power source frequency.
Check for: 
- Not using regular power source frequency. 
- Faulty power frequency sense circuit.
9E1
Electronic control problem.
(Over Voltage Error)
Check for:
- Check PCB and Wire harness.
- Check Power supply.
AE
Electronic Control Problem.
(Communication Error)
Check for: 
- Check PCB and Wire harness.
- Replace PCB.
EEE
Invalid state of Eeprom 
communication.
Check for : 
- PCB with Eeprom circuit.
HE
Invalid heating Temp in running 
the dryer.
Call customer service.
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to dryer before 
servicing, unless testing requires power.