4
Data Display Mode
Definition of Temperature Display Mode:
Display Mode 0 : Temperature data (Celsius)
Display Mode 1 : Average Touch Sensor data for 1 minute
Display Mode 2 : Average Temperature (Celsius) data for 1 minute 
How to Enter:
With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until the dryer beeps.
If no keys are pressed for 5 minutes, Data Display Mode will terminate.
Press the AdjustUp Key to increase the Display Mode ID.
Press the AdjustDown Key to decrease the Display Mode ID.
• Converting °C  °F
Celsius(°C)
-30
-10
10
30
50
70
F =9/5C + 32
Fahrenheit(°F)
-22
14
50
86
122
158
System Check Mode
Definition of System Check Mode:
“ 02 ” will display.
System Check Mode (02 mode) Progress Function Performed Start/Pause  
Motor (CW) Relay On  Heater Relay On  Heater Relay Off, Motor (CW) Relay Off
How to Enter:
While in Power Off, press the Dry Level + Power keys simultaneously to put the dryer into the
System Check mode.
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to dryer before 
servicing, unless testing requires power.