Gaggenau VG424210CA 설치 설명서

다운로드
페이지 48
13
5
Flush installation only : it is imperative to test 
functioning before jointing! 
Joint the surrounding 
gap with a suitable, temperature-resistant silicone 
adhesive (such as OTTOSEAL
®
S 70). Smoothen 
the seal joint with smoothing agent recommended 
by the manufacturer. Observe the notes on 
processing the silicone adhesive. Do not operate 
the appliance until the silicone adhesive has dried 
completely (at least 24 hours, depending on room 
temperature).
NOTICE:  Unsuitable silicone adhesive used on 
natural stone worktops will cause permanent 
discoloration.
Connect Gas Supply
The appliance is shipped from the factory for use with 
natural gas. It must be converted for use with propane. 
A qualified technician or installer must do the 
conversion.
Before connecting the appliance, please check 
whether the local connection conditions such as gas 
type and gas pressure match the appliance settings.
Make sure the gas supply is turned off at the manual 
shut-off valve before connecting the appliance.
The gas connection must be in a location that permits 
access to the manual shut-off valve and which, if 
applicable, is visible after opening the door of the 
cabinet.
SERVICER INFO ONLY
 
Connect the gas supply using the ½" U.S.A. elbow 
and the fiber gasket supplied with the unit. The 
shorter, nontapered thread fits into the threaded nut 
on the hob. The longer, tapered U.S.A. thread is for 
the incoming gas supply. Vent the gas line, check for 
leaks. The gas pressure regulator is supplied with the 
unit and comes set for natural gas. To convert 
regulator to LP (propane) gas:
Make-Maxitrol Model RV 47 CL ½ PSIG
1
Remove the aluminum cap from the top of the 
regulator.
2
Remove the yellow plastic shaft from the cap by 
pushing it sideways until it pops out of the groove 
in the cap.
3
Turn the shaft over and push back into the cutout 
in the cap.
4
Replace the cap on the regulator.
Connect Electrical Supply
Before connecting supply cord to wall receptacle, 
make certain that gas shutoff valve and all burner 
controls are in OFF position.
Electrical connection (AC 110-127 V) is established 
by means of a connecting cord with a grounding 
contact plug connected to a grounded socket, which 
must also be accessible after installation of the gas 
cooktop.
Burner Cap Placement
The burner parts must be properly placed for the 
cooktop to function properly. If the burner parts are 
not properly placed, one or more of the following 
problems may occur:
Burner flames are too high.
Flames shoot out of burners.
Burners do not ignite.
Burner flames light unevenly.
Burner emits gas odor.
Placing Burner Parts
 
After electrical connection is complete, assemble the 
burner parts correctly and evenly. When assembling 
the burner parts, make sure that the burner head is 
placed on the base in such a way that the prongs of 
the burner cap fit snugly into the groove of the burner 
base.
Checking Burner Cap Placement
 
Check to make sure that there is no gap between the 
burner parts. You may gently try to move the burner 
parts from side to side to check if they are properly 
placed.
Check the Installation
Check operation of electric igniters. Check flame 
characteristics. Flame should be blue with no yellow 
tip.
Yellow Flames:
 
Further adjustment is required.
Yellow Tips on Outer Cones:
 
Normal for LPG Gas.