The low-setting nozzles are located in the gas 
valve and are screwed in from the front. Turn the 
plastic part on the gas valve so that the recess is 
above the respective nozzle. Unscrew the nozzle 
and pull it out with a small pair of pliers.
5
Fully screw in the new low-setting nozzles as 
detailed in the table of nozzles.
6
Slide the spindles onto the gas valve and firmly 
tighten the locking screws. Fit and firmly tighten 
the cover plates.
Replacing the main nozzles
1
Detach the securing clips from the burner pipes. 
Unscrew the burners and extract the burner 
pipes. The electrode can be left connected. 
Extract the burners from the burner pipes.
2
Extract the nozzles from the burner pipes by hand 
and extract the O-ring.
3
Check correct fitting of the O-ring in the new 
main nozzles. Slide the nozzles onto the burner 
pipes. Do not bend the burner pipes!
4
Fit the burners onto the burner pipes. Fit the 
burners. Screw down the burners.
5
After loosening the screw, adjust the outer 
burner's air regulation sleeve to the correct 
dimensions (see nozzle table - L1). Tighten the 
screw again.
6
By turning or moving it, adjust the inner burner's 
air regulation sleeve to the correct dimension 
(see nozzle table - L2).
7
Fit the cooktop and screw it down evenly. Fit 
burner parts and pot supports, paying attention to 
correct positioning.
8
Set the pressure regulator to the correct pressure 
(see “Connect gas supply”).
Checking functions after the conversion:
 
The flames are adjusted correctly if no yellow tips are 
visible. They must not go out when switching over 
swiftly from the high to the low setting.
Note:  Stick the adhesive label included with the 
nozzle set over the rating plate of the appliance to 
document the changeover to a different gas type.