The  two  top  illustrations  demonstrate  how  the  slide-in  type  unit  is  designed  to  fit  into  open-  front 
enclosures, and supported at the Countertop. 
 
Do not install this unit under unprotected flammable  surfaces. Do  not  install  or  use  this 
appliance inside a building, garage, or any other covered area. It must not be used in or on 
recreational vehicles or boats.
 
 
INSTALLER  NOTE: 
This unit  should be installed so that it can be removed at a later date if factory 
service is required. Any protrusion into the side burner enclosure may prevent the unit from sliding into 
place.
 
 
ENSURING PROPER COMBUSTION AIR AND COOLING AIR FLOW 
 
You must maintain proper air flow for your side burner to perform as it was designed. If airflow is blocked, 
overheating  and  poor combustion will result. Make sure not to block  the  1"  front  air  inlet  along  the 
bottom of the face or more than 75% of the support grid surface with pans or griddles. 
 
For Built-in Installations 
A  side  burner  is  designed  for  easy  installation  into  masonry  enclosures.  For  non-combustible 
applications,  the  side  burner  drops  into  the  opening  (as  shown  in  cut-out  detail  -  Fig.  A)  above  or 
below depending on space, and hangs from its counter top trim. A deck is not required to support it from 
the bottom. 
  Two ventilation holes, of at least 20 sq inches in size, must be present to help release any gas 
from a leak. 
As Propane is heavier than air, locate your vents at the tank valve height or lower 
  The deck ledges and counter should be flat and level in reference to the floor. 
  LP TANK STORAGE AREA MUST BE ISOLATED FROM SIDE BURNER AND VENTED.